Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/18/2004 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 03/16/2004 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) GROUNDED CONDUCTOR OF NM CABLE NOT TO BE USED AS A UNGROUNDED CONDUCTOR (HOT) 200-7 2) SHEET METAL SCREW NOT ALLOWED AS A GROUND SCREW 250-8 3) PLEASE VERIFY SIGN PERMIT |
| 03/12/2004 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) RISER TO BE SUPPORTED BELOW ROOF. 2) CHASE NIPPLE NOT APPROVED FITTING FOR LB. 3) WE HAVE A GROUNDED CONDUCTOR CONNECTED TO A BREAKER. |