Inspection History: ELECTRIC - FINAL
Permit Number - T04EL00349
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/14/2004 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 06/11/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*. No compliance with note #1. Install bushing or use romex connector in back of sub-panel |
|
| 03/11/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0245*/ 1) SEPERATE NEUTRAL AND GROUNDS IN SUB-PANEL. 2) RECEPTS IN SHED NEED TO BE GFCI PROTECTED. 3) USE APPROVED SUPPORTS FOR 1" PVC CONDUIT. SUPPORT AT SUB-PANEL END ALSO WITHIN 12" |