Inspection Status: Approved
Inspection History: ELECTRIC - CABLE DROP
| Date |
Description |
Inspector |
Results |
Comments |
| 03/03/2004 |
ELECTRIC - CABLE DROP |
|
Approved |
IVRS - Inspection 0000* SENT TO TEP ON 03/04/04AM |
| 03/02/2004 |
ELECTRIC - CABLE DROP |
|
Denied |
IVRS - Inspection 0210*/ 1) THE GAS AND WATER PIPES MUST BE BONDED TO THE SERVICE PANEL. 2) THE UFER GROUND MUST BE LANDED AND TERMINATED IN THE MAIN PANEL INSTEAD OF THE METER CAN. THE GROUND MUST BE READILY INSPECTABLE, SO IT CANNOT BE LOCATED IN A T.E.P. SEALED SECTION. 3) STRAP THE GROUND WIRE SECURELY TO THE WALL. 4) REMOVE THE OLD GROUND WIRE. 5) SINK ROD ENDS 2" BELOW GRADE. RECALL WHEN READY. |