Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/23/2004 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 03/11/2004 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ ALL FORIEGN SYSTEMS TO THE ELEC. SUBJVENT TO THE METER/COMBO PANELBOARD MUST BE REMOVED. SEE N.E.C. 99, 110-26 AND COMPLY. |
| 02/23/2004 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) RODS MUST BE 6' APART MIN. 2) SERVICE UPGRADED OVER EXISTING WATER LINES. IMPROPER CLEARANCES - NEC 110.26. 3) NEED GAS BOND. 4) USE ONLY BREAKERS LISTED FOR THIS PANEL BOARD. 5) NEED PERMANENT METAL ADDRESS TAG, WITH SCREWS. |
| 02/19/2004 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0920*/ LOCKED - PLEASE RECALL INSPECTION. |