Permit: T04EL00065

Parcel: 122092010


Addresses:

4134 E SENECA ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/09/2004 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/04/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) BOND ENCLOSURE PER 250-148. 2) BULB WIRE NUT LISTED FOR NOT LARGER THAN 2 #8 CONDUCTOR, 110-3. 3) BREAKER TO BE LISTED FOR USE BY MANUFACTURER - 110-3 - GE NOT FOR MURRAY. 4) FITTINGS TO BE FOR WEATHERPROOF USE.
03/15/2004 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) INSTALL GROUNDING ELECTRODE SYSTEM AS PER CODE 250-50 AND 250-52. 2) LABEL CIRCUIT BREAKERS. 3) CONNECT BONDING JUMPER. 4) USE CORRECT SIZED CONDUCTORS FOR AMPACITY AND DERATED PER 310-15 AND 310-16. 5) OLD DISCONNECT WILL NOT BE ALLOWED FOR JUNCTION BOX OR PASS THROUGH. 6) PLEASE VERIFY WATER BOND..