| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2008 | INSP - FOLLOW UP CODE ENFORCE | Approved | TALKED WITH OWNER GLEN, SET APPT FOR 10-28 9:30 AM | |
| 12/13/2007 | INSP - FOLLOW UP CODE ENFORCE | Approved | MET WITH GLEN ON HIS WAY TO WORK SET UP FOR RE-INSP TOMORROW 1/14/07 @9:30AM - RESHCEDULE FOR NEXT FRIDAY 12/21/07. | |
| 06/11/2007 | INSP - FOLLOW UP CODE ENFORCE | Approved | PERMITS STILL GOOD, NEW EXPIRATION DATE 10-06-07. PLEASE SCHEULE FOR 10-6-07.PN | |
| 11/23/2005 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 11/23/05, VISITED SITE, TOOK PICTURES, MET WITH OWNER GLENN, WHO SHOWED WHERE SOME PERMITS HAS BEEN SECURED, ASKED GLENN WHY NO HAS BEEN FINALED HE EXPLAINED THAT HE TOUGHT THAT THIS IS ALL HE NEEDED, EXPLAINED TO GLENN HE NEEDS TO CALL D.S.D. FOR FINAL INSP. HE STATED HE WILL GO BACK DOWN AND FINISH GETTING ALL PERMITS AND FINAL THE ONES HE GOT, MOST OF WORK TO BACK STRUCTURE HAS BEEN COMPLETED WITH EXCEPTION TO FINAL INSP. ON PERMITS. GRANTED EXTENSION 3 WEEKS FOR PERMIT ISSUES. | |
| 09/29/2005 | INSP - FOLLOW UP CODE ENFORCE | Approved | NO PERMITS IN PERMITS PLUS | |
| 03/04/2005 | INSP - FOLLOW UP CODE ENFORCE | Approved | 2/24/05 MET WITH SIMONA NUNEZ, FROM T.E.P. SIMONA AGREED THAT CONNECTIONS ARE NOT CORRECT, DOES NOT KNOW WHY CLEARANCE WAS NOT DONE, DID FIND THAT 2ND BOX SUPPLIES SERVICE TO ANOTHER STRUCTURE, AT ONE TIME POSSIBLY A SHOP.LOOKED INTO WINDOWS,STRUCTURE IS SET UP FOR LIVING QUARTERS.(WILL DO RESEARCH AT D.S.D.)TO SEE IF ALLOWED OR PERMITED, SIMONA STATED THAT SHE WILL TRY TO MAKE CONTACT WITH OWNER, NO ONE HOME AT THIS TIME. WILL SEND LETTER TO OWNERSTATING, THAT HE WILL NEED TO GET A PERMIT FROM DSDCONCERNING ELECTRIC, IF HE DOES NOT ELECTRIC WILL BE SHUT OFF IN 10 DAYS.SIMONA WILL FAX ALL INFORMATION TO ME. ALL INFORMATION I FIND ON PROPERTY WILL BE FAXED TO SIMONA. FOUND METER #1 GOES TO MAIN STRUCTURE, METER #2 GOES TO SECOND STRUCTURE. METER SHOWS A TODD HATHAWAY, 3402 N LOS ALTOS. (WILL DO RESEARCH AT D.S.D. PRIOR TO NOV) OWNER OCCUPIED, HAVE NOT BEEN ABLE TO DO COMPLETE INSPECTION, DUE TO OWNER STATED HE WILL CALL FOR AN APPOINTMENT.HE HAS NOT YET DONE THIS.LEFT A CARD IN DOOR WITH CONTACT NUMBER FOR INSPECTOR J. HURD. WILL DO FOLLOW UP METER #1 XH545653 14682692 METER #2 XH545654 14682693 CONTACT PERSON: TODD HATHAWAY 887-9302 3402 N LOS ALTOS |
|
| 03/01/2005 | INSP - FOLLOW UP CODE ENFORCE | Approved | 3/ 01/05 MET WITH OWNER AT SITE FOR INTERIOR INSPECTION OF STRUCTURES.TOOK PICTURES, FINDINGS AS FOLLOWS: MAIN HOUSE:LIVINGROOM MISSING COVER PLATES ON LIGHT SWITCHES AND ON RECEPTACLES. LIVINGROOM WINDOW REPLACED WITH GLASS BLOCK, NO LINTEL ABOVE OPENING. SLIDING GLASS DOOR INSTALLED IN OPENING NOT TO SPECS. HEATER FLUE PIPE JOINTS NOT SEALED.NORTHWEST BEDROOM REMOVED AND REPLACED WITH NEW DOOR (WORK WITH PERMITS) ROOM NOT A SLEEPING ROOM. KITCHEN HAS A HOLE IN CEILING, AND CRACKS THROUGHOUT DRYWALL. OUTLET BY SINK LOOSE FROM WALL, SHOWS OPEN GOUND. RANGE HOOD WIRED WITH ZIP CORD, NOT HARD WIRED. SOUTHWEST BEDROOM WINDOW HAS BEEN BLOCKED IN, NEW WINDOW INSTALLED, GOOD FOR EGRESS. WINDOW NOT COMPLETED. NEW WINDOW INSTALLED IN BATHROOM NOT COMPLETED. FRONT PORCH NOT BUILT TO SPECS, 2 BY 4'S OVER SPANNED, BEARING MEMBERS INSTALLED INCORRECTLY.BACK PORCH ALSO NOT BUILT TO SPECS, SAME PROBLEMS AS FRONT PORCH. FENCE BETWEEN YARDS BUILT FROM MULTIPLE MATERIALS, NEEDS TO BE REMOVED. EAST SIDE BLOCK WALL HAS BEEN ADDED ON TO IN A HAZARDOUS MANNER WITH NEW/ USED BLOCK INSTALLED WITH NO CODES IN MIND( KIND OF THROWN TOGETHER ). BACK STRUCTURE: FRONT DOOR HAS DBL KEYED DEADBOLT INSTALLED, DEADBOLT AND KNOB POSITION NEED TO BE REVERSED. HEATER IN LIVING NOT APPROVED TYPE, WORK WITHOUT PERMITS.NOT FAMILAR WITH GAS VALVE ON STOVE, MAY NOT BE APPROVED TYPE. OUTLETS SHOW OPEN GROUND, ELECTRICAL SYSTEM, 2 WIRE SYSTEM, 3 WIRE OUTLETS HAVE BEEN INSTALLED. OUTLET ABOVE KITCHEN COUNTER NOT GFCI PROTECTED.WINDOWS IN KITCHEN AND BEDROOM MISSING EITHER THE LOCKING MECHANISM OR THE HAND CRANK TO OPEN. BATHROOM WINDOW NOT OPERABLE, NEEDS VENTING. BATH TUB MISSING SHOWER HEAD.OUTLET IN BATHROOM ABOVE PEDESTAL SINK NOT GFCI PROTECTED.BROKEN OUTLET IN BEDROOM. PORCH POSTS AT BACK STRUCTURE INSTALLED IMPROPERLY, NEEDS POST BASE,( MAKE SURE ALL METAL HARDWARE IS INSTALLED TO SECURE ALL PORCH MEMBERS).ELECTRICAL PANEL- WIRES MISSING WIRENUTS, LOSE WIRES IN BOX JUST HANGING, NEED TO BE REMOVED. ( WILL RESEARCH ELECTRICAL,POSSIBLE WORK WITH PERMITS). BACK STRUCTURE POSSIBLE WORK WITHOUT PERMITS. BACK STORAGE AREA NEEDS TO BE REMOVED(NO PERMITS, STRUCTURE HAZARDOUS). UNITS BLOCK WALLS HAVE LARGE OPEN CRACKS, NEED REPAIRS.EXTERIOR PAINT, CHIPPING AND PEELING, STRUCTURE NEEDS TO BE REPAINTED. ELECTRICAL SWITCH, JUNCTION BOX AND ADDED OUTLET ON BACK PORCH OF MAIN HOUSE NEEDS TO BE REMOVED OR INSTALLED CORRECTLY. TRASH AND DEBRIS NEEDS TO BE REMOVED FROM ALL YARD AREAS. |