Case: T04DV00992

Parcel: 111031570


Addresses:

3168 E KLEINDALE RD


Inspection Status: Correction Required

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T04DV00992

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Correction Required

Date Description Inspector Results Comments
01/11/2005 INSP - INITIAL CODE ENFORCMENT Correction Required 1/10/05, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT KRISTINE WHO SHOWED WHERE CONVENIENCE OUTLET IN LIVING ROOM IS LOOSE AND WORN TO A POINT THAT WILL NOT HOLD PLUG, SHOWS OPEN GROUND UNDER TEST, FRONT DOOR LACKS PROPER WEATHER PROTECTION, LIGHT FIXTURE IN S/E BEDROOM DOES NOT OPERATE PROPERLY, PRESSURE RELIEF VALVE DRAIN LINE AT HOT WATER TANK IS NOT DIRECTED TO EXTERIOR OF DWELLING, ORIGINAL HOT WATER SUPPLY LINE HAS BEEN ABONDONED AND NEW COPPER LINE HAS BEEN ADDED TO STRUCTURE FEEDING ALL HOT WATER FIXTURES, BATHROOM HAS LIGHT FIXTURE WITH CONVENIENCE OUTLET INSTALLED NOT GFCI PROTECTED, BATHROOM SINK CONTINOUSLY LEAKS, ELECTRICAL PANEL OVER PROPECTED WITH 30 AMP DOUBLE POLE BREAKERS, ADDED ELECTRICAL CIRCUIT GOING UP AND ON TO ROOF TOP, NEW CONDUIT,