Case: T04DV00969

Parcel: 126121710


Addresses:

4633 E BURNS ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
01/05/2005 INSP - INITIAL CODE ENFORCMENT Approved TENANTS: JOSE & NORMA DEL CAMPO, TENANTS FOR 2 MONTHS 207-3536, RENTING 1 YEAR CONTRACT.

2 BEDROOM WINDOWS ON WESTSIDE PAD LOCKED.
2 BEDROOM WINDOWS ON SOUTHSIDE PAD LOCKED.
1 BEDROOM WINDOW ON SOUTHEAST SIDE PAD LOCKED.
DOOR BELL HANGING NOT SECURED.
FRONT DOOR LACKS WEATHER STRIPING, DAYLIGHT COMING THROUGH. WROUGHT IRON GATE DOES NOT WORK PROPERLY, (DONT OPEN).
LIVING ROOM: OUTLETS 2-PRONG OUTLETS.
DINNING ROOM: FAN CONTROL BROKEN EXPOSING WIRING, HAZARDS. FRONT DOOR INSTALLED, NO WEATHER STRIPPING TENANT/THRESHOLD CALLED TO PUT NEWS PAPER INPLACE OF WEATHER STRIPPING.
KITCHEN: COUNTER TOP OUTLET HAS 6-PRONG ADAPTOR. OUTLET 3' FROM SINK NOT G.F.I. PROTECTED. NOT PROPERLY WIRED. UNDER SINK OUTLET & SWITCH FOR ROMEX HANGING. ALSO HOLE IN WALL UNDER SINK FOR PLUMBING.
HALLWAY: EXPOSED WIRING FROM PREVIOUS LIGHT. SMOKE DETECTOR INSP.
MID/SOUTH BEDROOM: BARS ON WINDOWS PAD LOCKED.
WEST BEDROOM: 2 WINDOWS WITH BARS & PAD LOCKED.
HOT WATER CLOSET: MISSING CONDUCTIVE AIR DUST LOW & HIGH. NOT 18'' ABOVE GROUND.
NORTHWEST BEDROOM: OPEN GROUND ON EAST WALL OTHER OUTLET 2-PRONG, WROUGHT IRON BARS HAVE PAD LOCKS.
BATHROOM: NO G.F.I., VENT DOES NOT WORK.
GARAGE/MASTER BEDROOM: OPEN GROUNDS, WINDOW BAR PAD LOCKED. CHECK PERMIT FOR CONVERSION, MASTER BEDROOM, OPEN GROUNDS, NOT G.F.I. PROTECTED.
REAR PORCH: 32X16 OVER SPAN, 2X6, 15', 2' ON CENTER WITH (3) 4X12 BEEMS TO MAKE 32 FEET. SUPPORT POSTS 4X4 WOOD ON TOP OF CONCRETE SLAB. FOOTER ARE SEEN, NOT PROPERLY SUPPORTED TO STRUCTURE. WATER DAMAGE ABOVE ELECT. METER.
ELECTRICAL CONNECTION: FOR WASHING MACHINE NO PERMANT. SOURCE TO CONNECT. TENANTS USING EXTENSION CORDS TO OUTLETS BEHIND KITCHEN WALL (EXTERIOR) NOT G.F.I.
ELECTRIC PANEL: 60 AMP SERVICE TRIPLE LUGGED FEEDING SUBPANEL ON WESTSIDE OF MAIN CIRCUITS & GROUND CONNECTED ON SAME BAR. 50 AMP BREAKER FOR A.C.? BREAKER UPSIDE DOWN, 20 AMP & 30 AMP BREAKER IN SUB PANEL, 30 AMP UPSIDE DOWN. BREAKERS LOOSE, NEUTRAL & GROUNDS CONNECT ON SAME BAR. ADDED WORK POSSIBLE DONE WITHOUT PERMITS. 15 AMP IN SUB PANEL DOUBLE LUGGED FEEDING SPRINKLER SYSTEM.
SUB PANEL: IN HALLWAY NOT PROPERLY MARKED (BREAKERS) POSSIBLE WORK WITHOUT PERMITS.
TERMITE DAMAGE BETWEEN LIVING ROOM & DINNING ROOM.