Case: T04DV00966

Parcel: 10605091A


Addresses:

826 W PRINCE RD


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T04DV00966

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
02/21/2006 INSP - INITIAL CODE ENFORCMENT Approved RECIEVED CALL FROM BOB MILLS PIPE IT RIGHT CO. HAD SOME ISSUES REGARDING MASTER METER SYSTEM. SET ON SITE MEETING FOR 3PM.
ARRIVED ON SITE, MET WITH BOB AND RICK PARK MANAGER. ISSUES WITH SUPPORT OF GAS METERS. SUPPORTS WILL ONLY BE REQUIRED FOR METERS THAT ARE LONGER THAN 10 INCHES ON SUPPLY SIDE OF METER, INFORMED RICK THAT REPAIRS TO ALL METER BASE WILL DEPEND ON WEIGHT OF PIPING AND SHOULD BE ACCESSED BEFORE INSTALLATION OF SUPPORTS. ASKED RICK- PARK MANAGER OF STATUS REGARDING PLUMBING AND ELECTRICAL ISSUES. STATED ARTISIC PLUMBING HAS COMPLETED ACCESSING PLUNBING SYSTEM AND HAS FORWARDED ALL FINDINGS TO PLUMBING ENGINEER. SEVERAL ELECTRICAL DISCONNECTS HAVE BEEN ORDERED. PARK MANAGER WILL FAX INFORMATION REGARDING INSTALLATION OF THE NEWEST DISCONNECTS. SCHEDULE FOLLOW UP IN 45 DAYS.
01/19/2005 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE ON 2ND INITIAL INSPECTION. REMAINING UNITS WERE INSPECTED BY INSP. H. LOPEZ & J. ORTA, UNIT #'S WERE TRAVEL TRAILER L-8, VACANT & SECURED. GREEN HOUSE ADDRESSED 802 W. PRINCE - RENTAL HOUSE STRUCTURE & MANAGER HOUSE. SITE INSPECTION ALSO INCLUDED PARK SUPER HENERY, FOR DETAILS SEE ATTACHED NOTES MARKED L-8 GREEN HOUSE & MANAGER HOUSE.
01/19/2005 INSP - INITIAL CODE ENFORCMENT Approved INITIAL INSPT. - MANAGER HOUSE
C-12/C-15
T.C. SEC. 16-4 PERMITS REQUIRED:
1) NEW HVAC SYSTEM. HEAT PUMP/ROOF FASCIA AND COOLER ON ROOF.
2) ADDED CIRCUIT IN N.E. BATHROOM.
3) WATER HEATER REPLACED.
4) JACUZZI BATHROOM - GFCI - NO
5) KITCHEN RECEPT. NO - GFCI
T.C. SEC. 16-11 (A) FIRE SAFETY:
1) EAST BEDROOM NO SMOKE DETECTOR.
2) WEST BEDROOM NO SMOKE DETECTOR.
TC. SEC. 16-11 (B) HEATING,COOLING & VENTILATION SYSTEMS:
1) NEW DUCTING AND RETURN AIR GRILLS.
2) EXTERIOR WATER HEATER ENCLOSURE NEEDS CLEAN-UP.
3) EXTEND AND SUPPORT FLUE @ EXTERIOR WATER HEATER.
T.C. SEC. 16-11 (C) ELECTRICAL SYSTEMS:
1) REVERSED POLARITY @ WIRING ROOM SOUTH WALL - S.E. RECEPTACLE.
2) PANEL BOARD RM. CLOSET. IMPROPER CLEARANCE, IMPROPER BEDROOM, LACK K.O. SEAL, GROUNDS AND NEUTRALS COMBINED. ADDED CIRCUIT EXPOSED.
3) EAST BEDROOM - EAST WALL RECEPT. REVERSED POLARITY.
4) EAST BEDROOM - S. RECEPT. REVERSED POLARITY.
5) NO GFCI PROTECTION @ N.E. BEDROOM.
6) NO EQUIPMENT GROUND @ KITCHEN S.E. WALL RECEPTACLE.
7) PERMANENT EXTENSION CORD FOR RANGE IGNITION AND CONTROLS.
8) KITCHEN COUNTER RECEPT. NOT GFCI PROTECTED.
9) REVERSED NEUTRAL @ EAST WALL OF WEST BEDROOM.
T.C. SEC. 16-11 (E) PLUMBING SYSTEMS:
1) MIDDLE BATHROOM (BY KITCHEN) LAV. DRAINS INTO SHOWER.
2) EXTEND TRP DRIAN LINE @ EXTERIOR WATER HEATER
3) EXTERIOR FLUE AND SUPPORT - LACKING AT WATER HEATER.
MISC:
PARK SYSTEM ELECTRICAL LOCATED IN THEIR YARD, NO CUSTOMER ACCESS TO DISCONNECTS.
S.F.R. HAS 4 BATHROOMS.
01/19/2005 INSP - INITIAL CODE ENFORCMENT Approved INITIAL INSPT. GREEN HOUSE - 802 W. PRINCE
C-12/C-15
T.C. SEC. 16-4 PERMITS REQUIRED:
1) NEW WATER LINES UNSUPPORTED - NO INSPECT.
2) NEW GAS LINES UNSUPPORTED - NO INSPECT.
3) NEW - (ADDED) PANEL BOARD AT N. END OF BUILD.
NO PERMITS, NO CIRCUIT DIRECTORY, WORK CLEARANCES NEEDED.
4) BASE BOARD HEATER ADDED - NO PERMITS.
T.C. SEC. 16-11 (A) FIRE SAFETY:
1) BAMBOO DECORATIVE WRAP AROUND @ LIGHT FIXTURE IN S.E. BEDROOM.
T.C. SEC. 16-11 (B) HEATING,COOLING & VENTILATION SYSTEMS:
1) EXT. CORD USED FOR PERM. SELF/STANDING FURNACE
2) IMPROPER - NOT WORKING GAS CORK.
NOTE: HECTOR ORDERED MANAGER TO DISCONNECT THEIR HEATER.
3) S.E. BEDROOM PORTABLE SPACE HEATER BEING USED.
4) EXTENSION CORD USED AS PERMANENT WIRING FOR COOLER.
T.C. SEC. 16-11 (C) ELECTRICAL SYSTEMS:
1) PLANT IN FRON OF SERVICE VIOLATES CLEARANCE REQUIREMENTS.
2) SERVICE FUSING IMPROPER.
3) DOUBLE LUGGING AT SERVICE.
4) SERVICE DISCONNECT OPERATING MECHANISM RUSTED.
5) METER NEEDS ADDRESS.
6) IMPROPER TERMINATION OF ADDED PANEL BOARD @ N. END STRUCTURE.
INTERIOR:
7) RECEPT. @ LIVING N.E. AREA - OPEN GROUND.
8) FORCED AIR GAS HEATER WIRING NOT PERMANENTLY WIRED, USING EXTENSION CORD.
9) S.E. WALL LIVING RECEPT. - NO EQUIPMENT GROUND.
10) LIVING RM. N. WALL RECEPTACLE OPEN GROUND.
11) OPEN GROUND S.E. BED. RECEPTACLE.
12) BAMBOO DECORATIVE WRAP AROUND ON LIGHT FIXTURE NOT PART OF FIXTURE.
13) KITCHEN, EXTENSION CORD AS PERMANENT WIRING TO MICROWAVE, FOOD PROCESSER AND COUNTER COOKING APPLIANCE.
T.C. SEC. 16-11 (E) PLUMBING SYSTEMS:
1) @ EXTERIOR, NEW WATER LINES - IMPROPERLY SUPPORTED. NEW GAS LINE - UNSUPPORTED.
2) TPR VALVE - DRAIN MISSING, NO COLD WATER SHUT OFF FOR WATER HEATER SUPPLY, ADDITION OF PVC PIPING FOR WATER SUPPLY. (WATER HEATER ROOM - N. OF KITCHEN). ALTERNATIONS THROUGHOUT TO ORIGINAL PLUMBING - WATER LINES.
T.C. SEC. 16-11 (F) INTERIOR SURFACES & FEATURES:
1) WINDOW CRANK - NOT FUNCTIONING @ LIVING ROOM.
2) TERMITE DAMAGE @ LIVING ROOM.
3) WATER HEATER ROOM - CEILING OPEN.
4) LIVING ROOM CEILING - CRACKED.
T.C. SEC. 16-12 (A) EXTERIOR SURFACES/WEATHER PROTECTION,DILAPIDATED STRUCTURES:
1) N. WINDOW: DILAPIDATED, CRACKS - OPENINGS.
2) MULTIPLE PENETRATIONS INTO STRUCTURE - NOT SEALED.
3) WEST DOORWAY NEEDS PAINT AND SOME REPAIR.
01/19/2005 INSP - INITIAL CODE ENFORCMENT Approved INITIAL INSPT. UNIT - L.8 (T.T.) - STORAGE
UNIT VACANT & SECURED
C-12/C-15
T.C. SEC. 16-4 PERMITS REQUIRED:
1) NEW COOLER CIRCUIT. NEED PERMITS AND INSPECTION.
T.C. SEC. 16-11 (A) FIRE SAFETY:
1) SMOKE DETECTOR NOT WORKING.
2) SMOKE DETECTOR REQUIRED IN BEDROOM.
T.C. SEC. 16-11 (C) ELECTRICAL SYSTEMS:
1) IMPROPER CLEARANCE IN FRONT OF MAIN EXTERIOR FUSE BOX.
2) OVER FUSING OF T.T. CORD @ 30 AMPS.
3) LIFE LINE NOT R.V. RATED.
4) ADDED ROMEX EXTERNAL CIRCUIT.
T.C. SEC. 16-11 (E) PLUMBING SYSTEMS:
1) FLUE VENT NOT PROPERLY SECURED.
2) HOT WATER HEATER LACKING TRP DRAIN.
3) NO WATER HEATER SHUT OFF VALVE.
T.C. SEC. 16-11 (F) INTERIOR SURFACES & FEATURES:
1) TUB SURROUNDINGS ARE DETERIORATED. NOT WATER PROOF.
2) ESCUTCHEONS AND SHOWER HEAD - MISSING (IN BATHROOM).
T.C. SEC. 16-12 (C) STAIRWAYS,DECKS & PORCHES:
1) STAIRS & LANDING NOT SECURED TO STRUCTURE.
01/14/2005 INSP - INITIAL CODE ENFORCMENT Approved INITIAL INSPT. UNIT - W.1
C-12/C-15
TC. SEC. 16-11 (A) FIRE SAFETY:
S.D. ON N.E. BED. INOP: CENTRALLY LOCATED SMOKE DETECTOR NOT FUNCTIONING: S.D. IN KIT/LIVE. AREA WORKS - O.K.
TC. SEC. 16-11 (B) HEATING, COOLING & VENTILATION SYSTEMS:
EXHAUST FAN - KITCHEN SEIZING. REQUIRES REPAIRS.
TC. SEC. 16-11 (C) ELECTRICAL SYSTEMS:
(1) KIT. WALL RECEPT. EAST WALL SHOWS OPEN GRND: OPEN GRND. KIT. RECEPT. SOUTH WALL.
(2) LIVING RM RECEPT. LOOSE CONNECTION. N. WALL: HALL LITE FLICKERING, LOOSE?
(3) 40 AMP LIFE LINE TO 50 AMP BREAKER.
(4) SERVICE EQUIPMENT MARKED W-1-6 L-18 LACKING 3' CLEARANCE & ID TO WHAT IT SERVES.
TC. SEC. 16-12 (A) EXTERIOR SURFACES/WEATHER PROTECTION, DILAPIDATED STRUCTURES:
(1) NEITHER STRIPPING AT 2ND DOORWAY, DETERIORATED:
(2) TREE BRANCH EXTENDS OVER TOP OF TRAILER, WILL REQUIRE TRIMMING.
TC. SEC. 16-12 (B) FOUNDATIONS WALLS AND ROOFS:
BOTH STAIRS & DECKS NOT ATTACHED TO STRUCTURE. 1- LACKING REQUIRED HAND RAILS.

(2)
01/14/2005 INSP - INITIAL CODE ENFORCMENT Approved INITIAL INSPT. UNIT - A.6 (M.M.)
C-12/C-15
TC. SEC. 16-11 (A) FIRE SAFETY:
(1) EAST BEDROOM - NO SMOKE DETECTOR.
TC. SEC. 16-11 (C) ELECTRICAL SYSTEMS:
(1) NO DISCONNECT - NO PEDESTAL FOR MOBILE HOME UNIT.
(2) NO STRAIN RELIEF FOR INTERIOR PANEL.
(3) REVERSED POLARITY AND NO EQUIP. GROUND AT EXTENDED BEDROOM AREA.
TC. SEC. 16-11 (J) ACCESS CONTROL:
(1) BOTH STAIRS AND LANDINGS NOT SECURED.
01/14/2005 INSP - INITIAL CODE ENFORCMENT Approved INITIAL INSPT. UNIT - C.7 (T.T.) 25X10
C-12/C-15
T.C. SEC. 16-4 PERMITS REQUIRED:
(1) GAS- PLUMBING MODIFIED, EG. NO HANGARS, GAPING HOLES IN T.T. WALLS - NOT SEALED.
T.C. SEC. 16-11 (A) FIRE SAFETY:
BEDROOM. S.D. NOT WORKING.
T.C. SEC. 16-11 (B) HEATING,COOLING & VENTILATION SYSTEMS:
(1) KITCHEN. EX. FAN. - SERVICE, BLADES RUBBING.
(2) EX. VENT FOR BATHROOM DOES NOT OPEN.
T.C. SEC. 16-11 (C) ELECTRICAL SYSTEMS:
(1) ROMEX AS LIFE LINE, FLANGED RECEPTACLE REMOVED. NON WEATHER PROOF RECEPTACLES AT PEDISTAL. INCORRECT AMPERE RATINGS.
(2) KITCHEN RECEPT. - OPEN GROUND.
(3) RECEPTACLE ON BATHROOM LIGHT FIXTURE TO BE REMOVED.
(4) ROMEX AND RECEPTACLE SUBJACENT TO CIRCUIT BREAKER BOX, EXPOSED AND IMPROPERLY INSTALLED.
(5) BOX FOR LIGHT.
T.C. SEC. 16-11 (E) PLUMBING SYSTEM:
(1) COLD WATER SHUT OFF MISSING, T&P VALVE MISSING. (2) WATER HEATER VENT PIPE BELOW ROOF LINE.
T.C. SEC. 16-11 (J) ACCESS CONTROL:
ENTRY STAIRS - NOT SECURED.
01/14/2005 INSP - INITIAL CODE ENFORCMENT Approved INITIAL INSPT. UNIT - A.13 (M.H.)
C-12/C-15
T.C. SEC. 16-11 (A) FIRE SAFETY:
(1) S.D. IN KITCHEN - NOT WORKING.
(2) EXISTING S.D. - NO BATTERY.
(3) S.D. IN BEDROOM BROKEN ATTACHMENT CLIP AND NO BATTERY.
TC. SEC. 16-11 (B) HEATING,COOLING & VENTILATION SYSTEMS:
(1) KITCHEN EXHAUST FAN - INOP.
(2) EXCESSIVE NOISE FROM FURNACE BLOWER MOTOR.
TC. SEC. 16-11 (C) ELECTRICAL SYSTEMS:
(1) EXT. RECEPTICAL NEEDS W.P. COVER.
(2) IMPROPER CLEARANCE @ 50 AMP POWER BOX @ 6'' ABOVE GRADE, UNDERNEATH M.H. UNIT, NO DISCONNECTING MEANS. (3) LIGHT FIXTURE @ NEAR EXIT DOOR IMPROPER - CORD CONNECTED.
(4) RECEPTACLE @ BATH INDICATES NO EQUIP. GROUND.
T.C. SEC. 16-11 (E) PLUMBING SYSTEMS:
(1) BROKEN TOILET SEAT.
T.C. SEC. 16-11 (F) INTERIOR SURFACES & FEATURES:
(1) FLOORING IS TEARING AT KITCHEN BY REF.
(2) KITCHEN WINDOWS NOT OPENING READILY.
(3) LIVING RM, WINDOW WILL NOT SHUT ALL THE WAY - OPEN - APPROX. 3''. THIS IS CAUSING FURNACE TO OPERATE EXTENSIVELY. (4) PANELING LOOSE AND TORN AT WALL IN LIVING ROOM ADJACENT TO LIVING RM. CLOSET.
(5) CEILING LEAKING AT SEVERAL LOCATIONS IN LIVING ROOM.
(6) CEILING IS 'WAVEY' DUE TO LEAKS.
*NOTE: ITEM (2) ADDENDUM: WATER ENTERED THROUGH EXTERIOR WALL - CAUSING WARPED - INTERIOR WOOD PANEL SEPARATED FROM WOOD FRAME.
(7) VANITY DRAWER BROKEN LOOSE AND DOOR DOESN'T SHUT.
T.C. SEC. 16-11 (J) ACCESS CONTROL:
(1) LANDING & STAIRS NOT SECURED AND E. LANDING REQUIRES PAINT. (2 LANDINGS NOT SECURED).
(2) EAST ENTRY DOOR DOES NOT CLOSE PROPERLY.
01/14/2005 INSP - INITIAL CODE ENFORCMENT Approved INITIAL INSPT. UNIT - L.10 (T.T.) APROX. 27X10
C-12/C-15
T.C. SEC. 16-4 PERMITS REQUIRED:
CHECK FOR PERMITS AND APPROVALS FOR WALL FURNACE IN KITCHEN AREA.
T.C. SEC. 16-11 (A) FIRE SAFETY:
(1) CARPET IMMEDIATELY UNDERNEATH GAS VALVE AND BURNER OF FURNACE.
(2) NO SMOKE DETECTOR FOR BEDROOM.
T.C. SEC. 16-11 (C) ELECTRICAL SYSTEMS:
(1) LIFE LINE:
A) WRONG SIZE, B) WEATHERED, C) LENGTH IMPROPER, D) ILLEGALLY SPLICED.
(2) COOLER CIRCUIT WIRED PERMANENTLY W/ EXPOSED EXTENSION CORD. NOTE: THIS IS ONE OF TWO LIFE LINES SUPPLYING TRAVEL TRAILER.
(3) LIVING ROOM HAS 3 PRONG RECEPTACLES W/ NO EQUIPMENT GROUNDS.
(4) LIGHT FIXTURE IN KITCHEN - MISSING.
(5) UNSECURE OPEN RECEPTACLE AT BOTTOM OF KITCHEN SINK.
(6) BREAKER BOX IN KITCHEN CABINET HAS EXPOSED SINGLE CONDUCTORS ENTERING 'KNOCK-OUT' OPENING - UNPROTECTED AND NOT SECURED.
(7) TWO LOCATIONS IN UPPER SHELVING IN SOUTH LIVING ROOM WALL HAS ROMEX WIRE. PROTRUDING FROM WALL, NOT PROPERLY TERMINATED IN BOX.
(8) PULL CHAIN FIXTURE IN BATHROOM LOOSE AND RECEPTACLE BUILD INTO FIXTURE NOT ALLOWED.
T.C. SEC. 16-11 (E) PLUMBING SYSTEMS:
1) BATHROOM LAVATORY:
A) NOT SECURED.
B) TEMP. PROPPED W/ 1X2 BOARDS.
C) MISSING HOT WATER HANDLE.
D) DRAIN LEAKING.
(2) SUPPORT STRUCTURE UNDER TUB - WEAK, ALLOWING TUB TO SINK WHILE IN USE.
(3) WATER HEATER:
A) VENT PIPE BELOW ROOF LINE.
B) SUPPLY SHUT OFF VALVE MISSING.
C) TRP VALVE PIPE NEEDS EXTENDING.
D) PENETRATION INTO UNIT NEEDS TO BE SEALED.
T.C. SEC. 16-12 (A) EXTERIOR SURFACES/WEATHER PROTECTION, DILAPIDATED STRUCTURES:
(1) PORCH STRUCTURE - (APPROX. 70X10)
A) DILAPIDATED, ROTTED.
B) IMPROPERLY SPANNED ROOF W/ 2X4 TRUSSED SPANNING OVER 4FT.
(2) STAIRS NOT SECURED AND NO HANDRAILS.
01/14/2005 INSP - INITIAL CODE ENFORCMENT Approved INITIAL INSPT. UNIT - L.11 (M.H.) APPROX. 30X10
C-12/C-15
T.C. SEC. 16-11 (B) HEATING,COOLING & VENTILATION SYSTEMS:
(1) EXHAUST KITCHEN FAN INOP. NEW FURNACE INSTALLED.
T.C. SEC. 16-11 (C) ELECTRICAL SYSTEMS:
(1) LIFE LINE INSTALLED IN NON WEATHER PROOF RECEPTACLE. AN ILLEGAL ADAPTER HAS BEEN INSERTED. (2) OPEN CONDUCTOR WIRING FOR METER BASE AND DISCONNECT SWITCH.
(3) LIVING RM. EAST WALL, S.E. RECEPTACLE - NO EQUIP. GROUNDS.
(4) LIVING RM. EAST WALL, N. SIDE RECEPTACLE COMING OFF WALL.
(5) EXPOSED ROMEX AND IMPROPERLY TERMINATED, ADJACENT TO RIGHT OF KITCHEN SINK. STRAIN RELIEF IMPROPERLY INSTALLED.
(6) NEED KNOCK-OUT SEALS WHERE CONDUCTOR WERE AT 1 TIME.
(7) PANEL BOARD REQUIRED MAIN BREAKER.
(8) ELECTRICAL CONDUCTOR NOT GROUNDED AS PER NEC REQUIREMENTS.
(9) BATHROOM RECEPT. TOP SHOWS NO GROUND.
T.C. SEC. 16-11 (E) PLUMBING SYSTEMS:
(1) WATER HEATER, T&P VALVE IMPROPERLY SIZED: WATER HEATER FLUE SYSTEM NOT PROPERLY SECURED, NO COLD WATER SHUT OFF: WATER HEATER ENCLOSURE NEEDS CLEANING.
(2) BATHROOM SHOWER FAUCET LEAKING, SHOWER ENCLOSURE IN A DETERIORATED CONDITION & NO LONGER WATER PROOF.
T.C. SEC. 16-11 (F) INTERIOR SURFACES & FEATURES:
(1) NORTH BEDROOM, CEILING MATERIAL PERFORATED.
(2) KITCHEN/LIVING CEILING REPAIRED, NOT COMPLETED.
T.C. SEC. 16-11 (J) ACCESS CONTROL:
(1) BEDROOM (SOUTH) WINDOW CRANK INOP.
T.C. SEC. 16-12 (A) EXTERIOR SURFACES/WEATHER PROTECTION, DILAPIDATED STRUCTURES:
(1) EXTERIOR WINDOWS AND OPENINGS ARE TAPED. TENANT CLAIMS DRAFT FROM ALL OPENINGS.
(2) SIDING NOT SECURED TO UNIT AT VARIOUS LOCATIONS.
(3) STAIRS NOT SECURED.
T.C. SEC. 16-12 (C) STAIRWAYS, DECKS & PORCHES:
ENTRY STEPS & LANDING ON WESTSIDE NOT SECURED TO STRUCTURE.
MISC:
ALL OPENINGS, WINDOWS NO HARDWARE TO OPEN.
12/14/2004 INSP - INITIAL CODE ENFORCMENT Approved CONTACTED PARK MANAGER
ON SITE. SPOKE WITH HENRY ACCORDING TO HIS INFORMATION TIRES WERE ACCENDENTLY THROWN IN, BUT WHERE DUG UP & REMOVED. STATED PROOF CONSISTING OF PHOTOS & INFORMATION WAS SENT TO AGENCY INVOLVED WITH OVER SEEING POOL FILL IN. ASKED HENRY TO PROVIDE SOME INFORMATION SENT TO AGENCY. HE AGREED & WILL PROVIDE INFORMATION.
TENANT STATED SECTION OF SEWER HAS BEEN REPLACED.
ADDRESS - PARK LIGHTING
VENT STACKED BEHIND H-7 - STEEL
ASKED HENRY IF PERMIT WAS PULLED & HE STATED NO PERMIT WAS APPLIED FOR. TOOK PICTURES OF 2-SEPERATE DIGS OF POOL WORK DONE PROVIDED BY LARRY. STATED PICTURES SHOW WHEN TIRES WERE DUG UP. HENRY ALSO STATED BOTTOM OF POOL WAS BROKEN OUT.
12/13/2004 INSP - INITIAL CODE ENFORCMENT Approved ON SITE, INTL/INSP.
ADDITION OF WATER LINES.
ADDITION OF WASHING MACHINE DRAIN TO SEWER - NO P-TRAP.
87 GAS LINES REPLACEMENT MAY HAVE BEEN DONE UNDER PERMIT.
P.D.Q. REC'S 1 TEST FOR BACK IN 1-MONTH.
GRAHAM JONES - ELECTRICAL REPAIRS FOR PARK AS WELL AS GENERAL MAINTENANCE FOR PARK.
PANEL AT A-3 MASTER METER - ALTERNATIONS TO DISCONNECTS.
HOT WATER HEATER NEEDS ADDRESSING.
EXPOSED ABS FOR SEWER DRAINS - NEED ADDRESSING.
COOLER STAND & AC STANDS
ADDRESSING -
STRUCTURE - LAUNDRY ROOM - MANAGER HOUSE, STRUCTURE 2, REC. ROOM - OFFICE.
E.S. CAN BE BROUGHT IN.
PRIVATE WELL SUPPLY WATER - SOURCE INDICATES WATER DOSE NOT GET TESTED AS REQUIRED.
CITY WATER SYSTEM ON STAND BY.
12/13/2004 INSP - INITIAL CODE ENFORCMENT Approved ELECTRICAL VIOLATIONS:
INITIAL PARK INSPECTION BY HECTOR LOPEZ AND MYSELF REVEALED SIGNIFICANT N.P.O. VIOLATIONS CAUSED BY A LACK OF MAINTENANCE AND DISREGARD FOR PROPER PROCEDURES FOR MAKING REPAIRS, ADDING AND MODIFYING THE PARKS ELECTRICAL SYSTEM.
THE PARK DISTRIBUTOR SYSTEM AND ALL RELATED FACILITIES ARE PROVIDED BY THE MOBILE HOME PARK ITSELF AND SEVERAL SERVICE POINT ARE PROVIDED BY THE SERVING UTILITY WHICH IS TUCSON ELECTRIC POWER. THIS IS A PARK MASTER METERED SYSTEM.
THREE MASTER METERED AREA ARE PROVIDED THROUGHOUT THE THREE PARCELS WHICH CONSTITUTE THE PARK PROPERTY. A FOURTH LOCATION OF A SERVICE POINT IS LOCATED AT AND FOR THE PROPERTY WATER WELL SYSTEM WHICH SUPPLIES ALL OF THE POTABLE WATER FOR DRINKING, WASHING AND IRIGATION.
AS PREVIOUSLY STATED A MYRIAD OF ELECTRICAL HAZARD EXIST, THE COMPILATION BELOW ARE NOT COMPLETE, OTHER ISSUES MAY EXIST.
1. FUSED DISCONNECT SWITCHES FOUND TO BE DILAPITATED, NON FUNCTIONING, RUSTED.
2. IMPROPER OVER CURRENT PROTECTION.
3. GROUNDING AND GROUNDED CONDUCTOR ARE TERMINATED IN A COMON BAR WHERE 'SUB' ELECTRICAL EQUIPMENT IS INSTALLED.
4. GROUNDING ELECTRODE, GROUNDING ELECTRODE CONDUCTOR LACKING WHERE A SEPARATE STRUCTURE OR BUILDING HAS OCCURED.
5. PEDESTALS LACK GROUNDING ELECTRODE SYSTEM.
6. AN EFFECTIVE GROUNDING SYSTEM AS REQUIRED BY THE CODE HAS BEEN COMPROMISED DUE TO THE INSERTION OF PVC WATER LINE EITHER AS A REPLACEMENT OR REPAIR.
7. THE SOCKETS AND TERMINAL BASE FOR THE OLD FUSE BOXES HAVE BEEN 'GUTTED OUT' AND CIRCUIT BREAKER INSTALLED. THIS VIOLATOR 'LISTING' REQUIREMENTS AS PROVIDED FOR IN THE ELECTRICAL CODE. THE CIRCUIT BREAKER ARE LOOSE, NON FUNCTIONING AND SEVERELY WEATHERED.
8. OLD OPEN TYPE OF ELECTRIC METERS ARE A HAZARD, OPEN TERMINALS, EXPOSED SINGLE CONDUCTOR WIRING, MISSING DEAD FRONTS.
9. ACCESS TO PEDESTAL ELECTRICAL EQUIPMENT BELOW 21ST AND IMPROPER WORKING CLEARANCES. SOME OBSERVATION IS THAT SOME DOORS COULD NOT OPEN A MINIMUM OF 90 DEGREES.
10. THE STRUCTURE SUPPORTING ELECTRICAL EQUIPMENT IN BOXES, CONDUIT AND WIRING IS DILAPITATED, LOOSE, ROTTING, UNSOUND AND UNFIT FOR SUPPORT.
11. NO PERMANENT 'TAGGING', DIRECTORIES OR FORM OF IDENTIFYING SERVICE LOCATIONS, FEEDER AND BRANCH CIRCUIT DESTINATION.
12. RECEPTACLE CONFIGURATION ARE NOT COMPATIBLE WITH RATED AMPREITIES AND WIRE SIZES, ALSO AT SOME AREAS THE WRONG RECEPTACLE RATING HAS BEEN MISAPPLIED FOR TRAVEL TRAILER AND MOBILE HOME PEDESTALS.
13. ACESSORY STRUCTURE ALSO WIRED WITH OUT PERMITS, EVIDENCED BY THE WORKMANSHIP (OR LACK OF), BURIAL DEPTH, OPEN WIRING, UNPROTECTED WIRING.
14. LIFE LINES NOT LISTED FOR MOBILE HOME USE, RATINGS NOT SET AMPED ON CODE, LIFE LINES
INCORRECTLY INSTALLED, TERMINATED. LIFE LINES ARE IMPROPERLY SPLICED, FRAYED AND PRICED TOGETHER.
15. LIGHTING FIXTURE AND POLES THROUGHOUT WERE FOUND TO TAKE THE PROPER GLOKES AND OUTLETS SUCH AS RECEPTACLES WERE NOT WEATHER PROOF.
16. THE WATER WELL AREA/STRORAGE FACILITY AND ALL ASSOCIATED EQUIPMENT ARE ROTTED, NONFUNCTIONING AND THE ENCLOSURE WIRING GUTTER SPACE OVERFILLED W/ CONDUCTOR. (PER N.E.C. CUBIC INCH CAPACITY ALLOWANCE.