Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/02/2007 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | OFFICE MEETING: 2/2/07. MEETING TO INCLUDE MYSELF, INSP HURD, IMMEDIATE SUPERVISIOR RICK SALDATE, OWNERS OF SUNLAND MOTEL PATEL BEENABAHEN B & BHARGAVKUMART, ARCHITECT KEITH WHINNY, AND ATTORNEY FOR OWNERS OF SUNLAND MOTEL ROBERT KUHN. WENT OVER ISSUES CONCERNING SUNLAND MOTEL, LOT SPLIT. ATTORNEY IS WORKING ON GETTING THIS STRAIGHTENED OUT, WITH OLD OWNERS. KEITH CAN NOT SECURE PERMITS UNTIL THIS MATTER HAS BEEN RESOLVED. BUT IS STILL WORKING WITH D.S.D. KEEPING ALL PARTIES INFORMED ABOUT LEGAL ISSUES. WENT OVER ISSUE CONCERNING ELECTRICAL ISSUES AND ELECTRICAL DEMAND DUE TO LONG TERM STAY AND USING SPACE HEATERS FOR HEAT. ELECTRIAL ENGINEER HAS BEEN SECURED TO DUE NESSASARY INSPECTIONS, LOAD CALCULATIONS, DRAWINGS, THIS HAS BEEN COMPLETED. KEITH WENT OVER ELECTRICAL IN MEETING SHOWING WHERE 2 SEPERAT PANELS WILL NEED TO BE REPLACED, THESE 2 PANELS SERVE UNIT 14,15,16. TALKED WITH OWNERS, AND IT WAS AGREED UPON THAT THESE UNITS WILL BE VACATED BY PLACING THE OCCUPANTS INTO OTHER UNITS, THIS WILL BE DONE IN A 1 WEEK PEROID. DOWNGRADING ELECTRICAL ISSUES. ATTORNEY MR. KUHN STATED DOES HAVE PAPER WORK DRAWN UP AS WE SPEAK AND WILL BE SENDING THIS OUT TO OLD OWNERS, CERTIFIED, MR. KUHN EXCEPTS THAT WHEN OLD OWNERS RECIEVE THIS MAIL IT SHOULD GO QUICKLY TO DEAL WITH LOT SPLIT, THEN PLANS BE REVISED, THEN RESUBMITTED, AND HOPEFULLY EXCEPTED, PERMITS ISSUED. ELECTRICAL ISSUES DOWNGRADED @ THIS TIME. |
|
| 02/02/2007 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 2/2/07 FAXED OVER ALL NOTES TO ATTORNEY MR. KUHN. | |
| 03/27/2006 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 3/27/06, NOTE: REVISITED SITE, TOOK PICTURES, TALKED WITH SUPERVISIOR RICK SALADATE ABOUT ISSUES AND TIME FRAME, DUE TO BEING CALLED AWAY BEFORE INSP. WAS COMPLETE ON EMERGENCY CALL AND CASE PACKET TEMPORARY LOST WILL START CASE TODAY. USING SAME CASE NUMBER. |
|
| 03/27/2006 | INSP - FOLLOW UP CODE ENFORCE | Approved | VISITED SITE, TOOK PICTURES, MET WITH OWNER BITI ON SITE. EXPLAINED I WAS THERE SOME TIME AGO AND I WAS LOOKING TO SEE IF ISSUES STILL EXIST, STARTED AT UNIT 17 HASP INSTALLED ON EXTERIOR OF DOOR, CAN LOCK FROM EXTERIOR, INTERIOR CONVINIENCE OUTLETS SHOW OPEN GROUND UNDER TEST AT NORTHWALL, ALSO OUTLET BROKEN, LIGHT FIXTURE MISSING BULB AND PROTECTIVE COVER, FRONT DOOR WEATHER STRIPPING DOES NOT SEAL DOOR AS INTENDED, USING SPACE HEATER, NO OTHER HEAT TO UNIT. UNIT 15 -3- PRONG CONVENIENCE OUTLETS SHOW OPEN GROUND UNDER TEST, SOME COVER PLATES BROKEN, CONVENIENCE OUTLET BEHIND TV IS WORN, LOOSE CONNECTION, CORD PLUG TARNISHED DUE TO OVER HEATING, GROUND PLUG HOLES HAVE BEEN PAINTED SHUT CANNOT TEST, A/C CONTROL KNOB MISSING, COOK STOVE MISSING BURNER CONTROL KNOBS, KITCHEN WINDOW DOES NOT OPEN FOR VENT. FRONT DOOR WEATHER STRIPPING DOES NOT SEAL AS INTENDED. USING SPACE HEATER FOR HEAT, NO OTHER HEAT TO UNIT. EXTERIOR: UNIT 15 FLUE PIPE TO COOK STOVE COMES DIRECTLY OUT OF WALL. DOES NOT GO UPWARD, ELECTRICAL SERVICE SHOWS 1 RED WIRE 2 WHITE WIRES CONNECTED TO A SINGLE BREAKER, UNIT 15 HAS BEEN REWIRED TO INTERIOR WIRING. EXTERIOR HAS HOLES AND CRACKS. CARPORT AT SOUTHEND BY 15-17 SHOWS DETERIORATION, LACK OF PROTECTIVE TREATMENT, 4X6 CUT AT TOP TO SUPPORT BEAM, APPROXIMATELY 1/2 HAS BEEN CUT, ADDED SPLICED, WOOD TO HELP SUPPORT. SERVICE PANEL #17 DOUBLE LUGGED FOR LIGHTING, MOTION DETECTOR, LOW VOLTAGE, HOT WATER TANK 17-18 NEW, LACKS COLD WATER SHUT OFF, GAS VALVE NOT READILY ACCESIBLE. ELECTRIC SERVICE FOR 19-20 MISSING DEAD FRONT BREAKER PLUG. ELECTRIC SERVICE AT RAMADA SUB PANEL, RED WIRE SHOWS OVER HEATING ON 20 AMP BREAKER APPROXIMATELY 1 1/2 " OF WIRE INSULATION BLACKENED, BUSS BAR SHOWS PITTING, DISCOLORATION DUE TO OVER HEATING, THIS WAS DISCONNECTED , ELECTRICIAN TO TRACE WIRES GOES UNDERGROUND, RAMADA DETERIORATING WOOD, CONNECTIONS DETERIORATING, SEPARATINGS, WOOD DETERIORATING, COMPLETE RAMADA LEANING TO THE NORTH SIDE QUITE A BIT. UNIT 12-14 ELECTRIC SERVICE DOUBLE LUGGED, NUETRAL BAR 1 BREAKER FOR MOTION DETECTOR, LIGHTING LOW VOLTAGE, HOT WATER TANK NEWER. UNITS 10-11 HOTWATER TANK LEAKING AT DRAIN VALVE, EXPOSED ROMEX COMING OUT OF BOX GOING ONTO ROOF, (ADDED CIRCUIT) OFFICE (REAR PORCH) ADDED ELECTRICAL CIRCUITS, ADDED PLUMBING WATER AND DRAIN LINES FOR WASHERS (2) SEVERAL EXTENSION CORDS BEING USED. UNIT 7 NEWER HOT WATER TANK, GAS VALVE NOT READILY ACCESSIBLE UNIT 3 ELECTRICAL SERVICE 14 GAUGE WIRE ON 30 AMP BREAKER. 2 SEPERATE BREAKERS MISSING DEAD FRONT PLATE, MISS MATCHING OF BREAKERS. UNIT 8 14 GAUGE WIRE ON 20 AMP BREAKER, EXPOSED ROMEX MISSING DEAD FRONT PLATE. OFFICE, OUTLET SHOWS REVERSE POLARITY, ANOTHER SHOWS AN OPEN GROUND, RESIDENCE SHOWS OPEN GROUND, ALOT OF TRASH AND DEBRIS IN YARD. |