Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T04DV00959

Parcel: 107051480


Addresses:

465 W MIRACLE MILE

Inspection Status: Correction Required

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
02/25/2005 INSP - INITIAL CODE ENFORCMENT Correction Required 2/18/05, VISITED SITE, TOOK PICTURES, MET WITH MANAGER CLIFFTON ON SITE, WENT OVER ISSUE'S ON UNIT 17, 15, CLIFFTON STATED THAT HE FINALLY GOT RESIDENTS OUT OF UNIT 15, CLIFFTON STATED THAT OWNER HAD JUST TAKEN BACK MOTEL WAS SELLING IT ON LEASE WITH OPTION TO BUY, DEFAULTED, NOW OWER IS REDOING ALL UNITS AS THEY BECOME VACANT, WALKED UNIT 15 IS VACANT AT THIS TIME, AND BEING REHABED FOR RENTAL, OLD RESIDENT HAS ABOUT 30 CATS IN UNIT, SMELLS BAD, DID FIND MINIMUM HOUSING ISSUES IN UNIT, STOVE MISSING CONTROL KNOBS, HOILE IN CEILING FROM LEAK, LIGHT FIXTURE HANGING FROM WALL, HOLE IN WALL IN BATH ROOM FROM WATER LEAK, FLOOR MISSING TILES AROUND TOILET,WINDOWS MISSING WINDOW CRANKS, SHOWER WATER VALVES NOT PROPERLY SEALED TO PREVENT WATER FROM ENTERING IN BEHIND ESCUCHEON PLATE, DRY WALL DETERIORATING FROM WATER LEAK.BATHROOM MEDICINE CABINET HAS HOLES AROUND EDGES, EXTERTIOR AIR CONDITIONER NOT PTOPERLY SEALED, NOT TRIMMED OUT PROPERLY. BATHROOM WINDOW BROKEN.
UNIT 17, CONVENIENCE OUTLEDT COVERS MISSING AND OR BROKEN, DOORS MISSING HANDLES,HOLE IN WALL BEHIND BATH SINK WINDOWS MIOSSING WINDOW CRANKS, SHOWER WATER SUPPLY VALVE MISSING HANDLE USING VISE GRIPS TO CONTROL WATER SUPPLY,HOLE IN WALL BY SHOWER DUE TO WATER LEAK, WALL A/C UNIT NOT TRIMMED OUT ON EXTERIOR SIDE,
EXTERIOR: ELECTRIC BREAKER BOX, MAIN LUG BROKEN AWAY FROM PANEL BOX-LOOSE AND JUST HANGING, SHOWS DOUBLING OF BREAKERS. EXPOSED ROMEX, ELECTRIC CONNECTIONS ON ROMEX EXPOSED, ALL WINDOWS HAS REBAR INSTALLED, CAN NOT OPEN WINDOWS, CARPORTS SHOWS EXPOSED RAW WOOD, BEAM NOT FUFLL BEARING ON POST, BEAMS SAGGING NOT PROPERLY SIZED, IMPROPER POST BASE, RAFTERS ARE SPLICED
INSP. 2 RICK CALLED US AWAY FROM PROPERTY DUE TO EMERGENCY WILL RETURN TO FINISH INSP.