| 07/28/2005 |
INSP - FOLLOW UP CODE ENFORCE |
|
Approved |
VISITED SITE AND TOOK PICTURES, MET WITH OWNER ON SITE, VERY LITTLE HAS BEEN DONE, ASKED OWNER ABOUT DOING WORK, HE STATED HE HAS BEEN BY BUT NO ONE IS HOME, TALKED WITH THE RESIDENTS, WHO CONFIRMED HE HAS BEEN OUT OF TOWN DUE TO FAMILY ILLNESS. WIFE WAS GOING TO SCHOOL IN AFTERNOON. AGREEMENT IS, RESIDENTS GAVE OWNER A KEYM RESIDENTS ARE ALSO HELPING OWNER WITH THE WORK. AS TALKING WITH OWNER, HE STATED HE WILL GET REPAIRS DONE, EXPLAINED ALL OPTIONS TO OWNER. KEEPING IN MIND TIME FRAME, OPTION 1 COULD KEEP THINGS THE WAY THEY ARE BY JUST TRYING TO DO ALL THE WORK IN A STRICT TIME FRAME, BECAUSE RESIDENTS HAVE NOT PAID RENT FOR 3 MONTHS, IF HE SO CHOOSES HE COULD HAVE THEM VACATE THE PROPERTY, THIS WOULD GIVE HIM A LOT MORE TIME TO DO ALL THE WORK, OR HE COULD USE THE PROPERTY TO SECURE A LOAN AND GET THE HELP HE NEEDS TO BRING THE PROPERTY BACK UP. OWNER ON FIXED INCOME, HAS VERY LITTLE MONEY TO WORK WITH. OWNER STATES HE WANTS TO FIX UP THE HOUSE AND SELL IT. TOO MANY HEADACHES. I EXPLAINEDTO OWNER HE NEEDS TO TAKE WEEKEND TO THINK OUT ALL HIS OPTIONS AND GET BACK WITH ME ON MONDAY 8\1 TO LET ME KNOW WHAT HE WANTS TO DO. HE AGREED. |
| 01/04/2005 |
INSP - FOLLOW UP CODE ENFORCE |
|
Correction Required |
1/4/05, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT MARY, INSP. SHOWS FRONT DOOR LACKS PROPER HARDWARE, LACKS DOOR HANDLE, DOOR THROW AND STRICKER PLATE, PLASTER MISSING FROM TOP OF DOOR STUCCO SCREENING SHOWING THROUGH, FRONT DOOR LACKS PROPER WEATHER STRIPPING, STRUCTURE LACKS PERMANANT SOURCE OF HEAT, USING GAS FIRE PLACE FOR HEAT SOURCE, LIVING ROOM CEILING HAS HAD DRYWALL REPLACED BUT NOT INSTALLED PROPERLY NOR FINISHED, KITCHEN FLOOR TILES ARE BROKEN AND CHIPPED THROUGHOUT, KITCHEN DOOR PANES ARE BROKEN OUT ALLOWING EXTERIOR ELEMENTS TO ENTER LIVING SPACE, LACKS PROPER WEATHER STRIPPING, KITCHEN CEILING DRYWALL FALLING INAREAS TAPE JOINTS NOT PROPERLY SEALED, HAS HOLES AND CRACKS THROUGHOUT, BEDROOM HAS 2 BROKEN WINDOWS, LACKS PROPER EGRESS, WINDOW WILL NOT OPEN, DRYWALL ON EAST WALL HAS BEEN REPLACED WITH 1/8' MASONITE BOARD, HOLES IN WALL, BATHROOM DOOR BROKEN, EXTERIOR SKIN FALLING OFF, BATH FLOOR MISSING FLOOR TILES, TOILET MISSING HANDLE, SINK HAS BEEN TURNED OFF DUE TO WATER LEAK, SINK IS NOT PROPERLY SECURED TO WALL, SHOWER AREA WALLS HAS HOLES EXTERIOR COATING DETERIORATED TO A POINT TO ALLOW WATER TO ENTER IN BEHIND COVERINGS AND DETERIORATE STRUCTURE, TUB MISSING DIVERTER SPOUT, CLOSET IN BATH MISSING DRYWALL FROM CEILING, CLOSET OFF BATHROOM HAS SEVERAL CRACKS IN DRYWALL, LIVINGROOM PLASTER CRACKED UNDER WINDOW, EXTERIOR FACIA BOARD DETERIORATED, LACKS PROPER SEALANT, EXTERIOR WINDOW FRAMES LACKS PROPER SEALANT, GARAGE IN REAR TO WEST SIDE HAS BEEN ENCLOSED, WAS USED AT ONE TIME AS DWELLING, NOW BEING USED AS STORAGE, HAS ELECTRIC INSTALLED FOR WASHER/DRYER, FRONT WINDOWS BROKEN OUT, EAST SIDE HAS SMALL PORCH INSTALLED DETERIORATED AND SUPPORT POST DETERIORATED AND TO SHORT SCABING WOOD TOGETHER TO MAKE FIT, NOT TO STANDARDS, GAS VALVE TO HOT WATER TANK NOT AGA APPROVED, PRESSURE RELIEF VALVE NOT PROPERLY INSTALLED, ELECT. BOX SHOWS DOUBLING ON BREAKER, MAIN BREAKER LACKS HOLD DOWN CLAMP, ADDITION ELECTRIC ADDED FOR WASHER/DRYER 30 AMP, ADDED CIRCUIT FOR CONVENIENCE OUT, EXPOSED ROMEX, CONVENIENCE OUTLET NOT GFCI PROTECTED NOR WEATHER PROTECTED, STRUCTURE SHOWS EVIDENCE OF STRUCTURE CRACKS AT SOUTHEAST CORNER, SOUTHWEST CORNER UNDER WINDOW IN LIVING ROOM, STRUCTURE HAS HAD APPOX. 4X25 ADDITION ADDED TO SOUTHEND OF STRUCTURE, COOLER ELECTRIC BOX SHOWS EVIDENCE OF BEING BURNT, BLOCK FENCING GOING MOSTLY AROUND PERIMETER DETERIORATED, LISTING AND LEANING, CRACKS FROM SEPERATION OF BLOCKS, LOST STRENGHT AND STABILITY. |