Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T04DV00748
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/14/2004 | INSP - INITIAL CODE ENFORCMENT | Correction Required | MET IN OFFICE WITH RICK S. WITH RESEARCH FINDINGS. DUE TO ALL THE EVIDENCE THE POOL ANS SPA BARRIERS WERE ORIGINALLY INSTALLED IN 1986 WITH PERMITS AND ACCEPTED BY AT THAT TIME THE BUILDING OFFICIAL AND THE COMPLAINT IN 1992 WHICH THE INSPECTOR FOUND THE ENCLOSURE BUILT TO CODE. A DECISION HAS BEEN REACHED TO CLOSE CASE. INSPECTOR CAMACHO FEELS HE HAS NO JURISDICTION IN THE MATTER DUE TO ALL THE ABOVE. INSPECTOR 2 SALDATE AGRESS. CLOSE CASE. | |
| 09/13/2004 | INSP - INITIAL CODE ENFORCMENT | Correction Required | INITIAL INSPECTION FOUND: INSPECTOR LOCATED 5 FOOT ENCLOSURE AROUND ENTIRE POOL AREA. 5 GATES IN TOTAL ALL SELF LATCHING AND SELF CLOSING AND SWING AWAY FROM POOL AREA. ENCLOSURE TO INCLUDE GATES ON EACH SIDE OF THE RECREATIONAL CENTER, THERE ARE NO BARRIERS FROM 2 6 FOOT FRENCE DOORS LEADING OUT FROM THE RECREATIONAL CENTER, 2 GATES AT NORTH END OF POOL AND 1 GATE LEADING TO APARTMENTS PARKING LOT ON WEST END. ALL GATES IN COMPLIANCE. NO VIOLATIONS FOUND. NO REPAIRS NEEDED TO ANY OF THE 5 GATES. ALL OPERATE IN A SAFE WORKING CONDITION. POOL AREA HAS A SECONDARY TODDLER 3 FOOT HIGH FENCE AROUND POOL AND SPA AREA WITH 3 GATES. THIS ENCLOSURE AND GATES ARE 3 FOOT HIGH. THESE GATES SWING IN THE DIRECTION OF THE POOL. INSPECTOR DOES NOT FEEL COMFORTABLE WITH THESE TODDLER FENCES.SECONDARY TODDLER FENCES AND GATES ARE THE ONLY BARRIER BETWEEN APARTMENTS 128,228,131,231,226,126,127,227,122,222,123,223,141,241,143 &243. CONTACTED RICK S. WITH FINDINGS AND CONCERNS WITH TODDLER FENCE. ALSO CONTACTED ANOTHER INSPECTOR WITH ENCLOSURE EXPERIENCE JAMES HURD. INSPECTOR HURD MET INSPECTOR CAMACHO ON SITE FOR AN EVALUATION OF POOL AND SPA ENCLOSURE. HE BELIEVES TODDLER ENCLOSURE MAY NOT BE TO CODE. TOOK MANY PICTURES ON SITE TO DISCUSS AT A LATER DATE WITH INSPECTOR 11 RICK SALDATE. (SEE PICTURES). MET IN OFFICE WITH RICK S. AND JAKES HURD TO DISCUSS PICTURES OF ENCLOSURES. INSPECTORS BELIEVE TODDLER FENCE IS IN VIOLATION AND IS A SAFETY HAZARD TO THE PUBLIC. RICK S. AGREES. A NOTICE WILL BE SENT. INSPECTOR CAMACHO WOULD LIKE TO DO SOME RESEARCH ON WHEN THE POOL AND BARRIERS WERE INSTALLED TO CLARIFY HIS JURISDICTION. DURING RESEARCH INSPECTOR FOUND APPROVED DRAWING S (WHICH INCLUDE TODDLER 3 FOOT FENCE AND GATES) FROM 9/5/86 SIGNED AND APPROVED BY THE BUILDING OFFICIAL. THE DRAWINGS ON RECORD ARE AN EXACT MATCH TO WHAT IS NOW ON SITE. NO MODIFICATIONS HAVE BEEN MADE TO THE POOL OR SPA ENCLOSURES. ALSO FOUND ON RECORD WAS A PAST COMPLAINT IN WHICH A DEVELOPMENT SERVICES INSPECTOR ANSWERED THE SAME COMPLAINT ON THE ENCLOSURE. HIS NOTES READ EXISTING BUILT TO CODE ON 12/02/92. POOL PERMIT FOUND BUILT 3/28/86 FINALED 9/18/86 WITH ORIGINAL DRAWINGS SUBMITTED AN EXACT MATCH TO WHAT INSPECTOR CAMACHO FOUND ON SITE. NO MODIFICATIONS FOUND. |