Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T04DV00691
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/22/2004 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE ON INITIAL INSP OF UNIT 2926. PRESENT WERE OWNER ED & PARTNER JEAN CREAGAN. DID INSPECTION OF EFFICIENCY UNIT . ELECTRICAL: (1) ALL RECEPTACLES WERE CHECKED GFIC IN BATHROOM IS GOOD, GFIC IN KITCHEN SHOWS HOT, NEUTRAL ARE REVERSED. (2) SOME 3 PRONG RECEPTACLES SHOW NO GROUND. (3) 3 RECEPTACLES IN KITCHEN ARE WITH IN 6 FEET OF WATER & WILL REQUIRE GFIC PROTECTION. (4) BASE BOARD HEATER IS NOT HARDWIRED TO ELECTRICAL SERVICE (PERMIT REQUIRED) WEATHER PROOFING. (5) ENTRY DOOR LACKING TRESHOLD & WEATHER STRIPPING. MECH: WALL FURNACE NOT WORKING HAS BEEN CAPPED OFF, D.S.D. WILL REQUIRE REMOVAL OF WALL FURNACE, STRUCTURE IS LACKING GAS SERVICE, HOT WATER IS PROVIDED BY MAIN HOT WATER TANK AT 2924 ADDRESS. TENANT HAS MICROWAVE FOR COOKING, GAS STOVE IS NOT HOOKED UP. PICTURES WERE TAKEN. |
|
09/10/2004 | INSP - INITIAL CODE ENFORCMENT | Correction Required | INITIAL SABER INSPECTION MET ON SITE WITH INSPECTOR MARTIN LOPEZ (ENVIROMENTAL SERVICES) AND FIRE INSPECTOR WAYNE CUMMINGS (TFD). ALSO OWNER (EDWARD) AND INSPECTOR HECTOR LOPEZ. DECISION REACHED FOR INSPECTOR CAMACHO, MARTIN LOPEZ AND CUMMINGS TO INSPECT TRI-PLEX 2930 N. WINSTEL (UNITS 6A, 7B AND 8C). INITIAL INSPECTION FOUND: UNIT 6A: INSPECTOR CAMACHO ENTERED UNIT WITH OWNER AND INSPECTOR MARTIN LOPEZ AND INSPECTOR WAYNE CUMMINGS. 2 TENANTS HOME. FEMALE IN WHEEL CHAIR AND A MALE TENANT. MALE TENANT HAD A SEIZURE AT BEGINNING OF INSPECTION. INSPECTOR CUMMINGS RADIOD FOR ASSISTANCE FROM SITE. RESCUE UNITS ARRIVED TO ASSIST TENANT. TENANT WAS TAKEN TO TMC FOR OBSERVATION. -ADDED PLUMBING HOT AND COLD WATER SUPPLY LINES FROM WATER HEATER. WITH 2" VENT SYSTEM. POSSIBLE WASHING MACHINE HOOK UP WITHOUT PERMITS. - BEDROOM WINDOW DOES NOT OPERATE PROPERLY FOR EMERGENCY EGRESS. WINDOW WILL ONLY OPEN APPROX. 5" ONLY. - BATHROOM SHOWER WINDOW DOES NOT OPEN FOR REQUIRED VENTILATION. -NEW GFCI OUTLET INSTALLED BEHIND WALL HEATER GRILL. -STOVE EXHAUST VENT HAS BEEN COVERED WITH PLYWOOD. DOES NOT OPERATE PROPERLY FOR VENTILATION. -WALL HEATER GAS SUPPLY LINE NOT OF APPROVED TYPE. FLEX LINE CONNECTED MUST BE HARD PIPED. -WAtER LEAK AT WATER HEATER SUPPLY LINE TO COOLER. -WATER HEATER B-VENT LACKS REQUIRED 1" CLEAREANCE AT ENCLOSURE LID. B-VENT IS NOT PROPERLY SECURED. -BATHROOM SINK IS NOT PROPERLY SECURED TO WALL. -BATHROOM COMMODE NOT PROPERLY SECURED TO FLOOR. -CRACKS IN MASONARY EAST BEDROOM WALL. -DOUBLE KEYED DEAD BOLT AT FRONT SECURITY DOOR NOT ALLOWING SAFE AND RAPID EGRESS. -BEDROOM DOOR KNOB DOES NOT OPERATE PROPERLY. -BEDROOM DOOR JAMB IN NEED OF REPAIR. DOES NOT ALLOW DOOR TO OPERATE PROPERLY IN CASE OF EMERGENCY. -FRONT ENTRY DOOR LACKS WEATHER STRIP AND SWEEP. DOOR IS DILAPIDATED IN NEED OF REPAIR OR REPLACEMENT. -WATER DAMAGE TO SHEETROCK AT BATHTUB BASE. -REAR FASCIA BOARDS WATER DAMAGED. -FRONT OVERHANG PLYWOOD WATER DAMAGED. UNIT (7B): -SMOKE DETECTOR IN BEDROOM DOES NOT OPERATE. -BEDROOM WINDOW DOES NOT OPERATE PROPERLY FOR EMERGENCEY ESCAPE OR RESCUE. WINDOW OPENS ONLY 5". -WALL FURNACE IN LIVING ROOM IN NEED OF SERVICE. COMBUSTIBLE DUST AND DOG HAIR AT BASE. WALL HEATER COVER NOT PROPERLY SECURED TO UNIT. -CONVENIENCE OUTLET IN LIVING ROOM BY WALL HEATER DOES NOT OPERATE PROPERLY. TOP HALF NO POWER AND NOT ON SWITCH. -KITCHEN STOVE EXHAUST VENT FAN DOES NOT OPERATE FOR VENTILATION. -KITCHEN SINK LEAKS AT TRAP. -BATH VANITY FIXTURE LEAKS. -EXTERIOR FRONT HOSE BIB LEAKS AT HANDLE. -TENANT STATES SHE HAS TICKS AT OUSIDE YARD AREAS. - FRONT EXTERIOR DOOR HAS ILLEGAL DOUBLE KEYED DEAD BOLT. -BROKEN WINDOW GLASS BEDROOM WINDOW. -FRONT EXTERIOR DOOR LACKS REQUIRED WEATHER STRIP AND SWEEP. -FRONT EXTERIOR DOOR TRIM DAMAGED. -LIVING ROOM WINDOW NOT PROPERLY SEALED. -FRONT EXTERIOR PLYWOOD OVERHANG WATER DAMAGED. -CRACKS IN MASONARY EXTERIOR EAST WALL. UNIT (8C): -POSSSIBLE ADDITION WITHOUT PERMITS TO SOUTH END ATTACHED TO MASONARY DWELLING. STRUCTURE IS OF WOOD FRAME CONSTRUCTION APPROX. MEASUREMENTS 12' X 22' WITH ELECTRICAL AND PLUMBING. POSIBLE GARAGE ENCLOSED TO HABITABLE SPACE. OWNER STATES HE PURCHASED BUILDING IN THIS MANNER. LARGE BEARING BEAM IN CENTER OF ADDITION IS SAGGING. BOTH EXTERIOR PST LIGHT FIXTURES STILL REMAIN ON THE INTERIOR. ONE IN THE KITCHEN THE OTHER IN THE CLOSET. - NO CENTRAL HEAT IN UNIT. TENANT USING A SPACE HEATER. -CONVENIENCE OUTLETS IN LIVING ROOM SOUTH WALL NOT PROPERLY SECURED TO WALL. -EXPOSED WIRING IN WATER HEATER ENCLOSURE. -EXPOSED WIRING KITCHEN FIXTURE. KITCHEN FIXTURE OVER SINK LACKS GLOBES. -CONVENIENCE OUTLET OVER BATHROOM VANITY IS NOT GFCI PROTECTED. - POSSIBLE NEW WATER HEATER INSTALLED WITHOUT PERMIT. -SHOWER FIXTURES LEAK. -BATHROOM VANITY NOT SECURED TO WALL. -INTERIOR WATER HEATER ENCLOSURE NOT WEATHER TIGHT. LARGE OPENINGS AND CRACKS IN CONSTRUCTION OF ENCLOSURE.FRONT DOOR LACKS WEATHER STRIP AND SWEEP. -EXTERIOR SIDING HAS NOT BEEN MAINTAINED. SIDING IS DILAPIDATED AND COMING LOOSE. ALL 3 TENANTS WERE PRESENT AND ALLOWED ENTRY OF ALL INSPECTORS DURING INSPECTIONS. |
|
09/10/2004 | INSP - INITIAL CODE ENFORCMENT | Approved | INITIAL INSP #2926 C12 MISC: UNIT WAS POSTED & TENANT HAD NOT ALLOWED ENTRY INTO STRUCTURE. OWNER WILL SUBMIT OF COPY OF POSTED NOTICE. TENANT MAY HAVE LEFT WRONG KEY. |
|
09/10/2004 | INSP - INITIAL CODE ENFORCMENT | Approved | INITIAL INSP #2924 C12 TC-SEC. 16-4 PERMITS REQUIRED: (1) POSSABLE ADDITION CARPORT APPEARS TO HAVE BEEN ADDED APPROX 15'' BY 40'' WITH ELECTRICAL, EVIDENCED BY EXTERIOR PLUMBING & SLIDING KITCHEN WINDOW OPEN INTO GARAGE AREA. (2) APPEARS FURNACE CLOSET WAS DONE WITH OUT PERMITS, EVIDENCED BY LACK OF SEPTEXATROM OF COMBUSTOM AIR & RETURN AIR, DOOR LACKING METAL COVERING AS WELL AS BASE. SOUTHEAST BEDROOM RAFTER HAVE BEEN SPLICED TOGETHER, SEE PICTURES. NOTICE DISREGARD, PERMITS ON FILE & IN PACKET. TC. SEC. 16-11 (A) FIRE SAFETY: LACKING SMOKE DETECTORS. TC. SEC. 16-11 (C) ELECTRICAL SYSTEMS: (1) RECEPTACLES IN LIVING ROOM LACKING GROUND. 3-PRONG RECEPTACLES APPEAR TO BE INSTALLED IN 2 WIRE SYSTEM. (2) GFIC IN KITCHEN LACKING GROUND. (3) EXPOSED ELECTRICAL JUNCTION BOX, LACKING COVER PLATE. (4) SEVERAL ELECTRICAL COVER PLATES MISSING IN LARGE STORAGE ROOM. (5) BATHROOM EXPOSED ELECTRICAL CONDUCTORS IN BATHROOM FROM LIGHT FIXTURE AND LACKING GFI. (6) LACKING SWITCH COVER PLATE. (7) SOUTHEAST BEDROOM, EXPOSED ELECTRICAL ROMEX LACKING CONDUIT. (8) BROKEN ELECTRIC IN WEST BEDROOM. TC. SEC. 16-11 (D) MECHANICAL SYSTEMS: (1) FLUE SYSTEM NOT INSTALLED PROPERLY 90% ELBOW AT CAP. (2) LACKING EXAUST FAN FOR VENTALATION. (3) SOUTH BEDROOM LACKING COOLER VENT. T.C. SEC. 16-11 (E) PLUMBING SYSTEMS: (1) TPR VALVE LACKING ON TOP OF TANK. (2) T-VALVE FOR COOLER LEAKING, BASE OF FURNACE CLOSET (MECH RM) IS WET, INTERIOR OF CLOSET IS IN A DETERIORATED & DELAPATATED. (NOTE) DISREGARD ITEM (1), LEAK IS FROM T-VALVE. T.C. SEC. 16-11 (F) INTERIOR SURFACES & FEATURES: (1) FLOORING IN GARAGE AREA HAS DETERIORATED SEVERAL TILES BROKEN & CRACKED. LARGE SECTION APPROX (LACKING COVERING) 8'X20'.(2) FURNACE ROOM DOOR IN DELAPATATED STATE, RUNNER IS PEELING AWAY & HAS SPLITERED. (3) HALLWAY CEILING PAINT SURFACE HAS BLISTERED. T.C. SEC. 16-12 (A) EXTERIOR SURFACES/WEATHER PROTECTION, DILAPIDATED STRUCTURES: GARAGE DOOR LACKING WEATHER STRIPPING & TRESHOLD. |
|
09/10/2004 | INSP - INITIAL CODE ENFORCMENT | Approved | INITIAL INSP #2928 C12 TC. SEC. 16-11 (B) HEATING, COOLING AND VENTILATION SYSTEMS: WALL FURNACE LACKING PROTECTIVE GRILL IN EAST BEDROOM. TC. SEC. 16-11 (C) ELECTRICAL SYSTEMS: (1) GFI LACKING GROUND IN KITCHEN. (2) GFI IN BATHROOM LACKING GROUNDING. TC. SEC. 16-11 (D) MECHANICAL SYSTEMS: (1) EXHAUST VENT LACKING FROM GRILL. T.C. SEC. 16-11 (E) PLUMBING SYSTEMS: EXTERIOR PLUMBING LACKING WEATHER PROTECTION. T.C. SEC. 16-11 (F) INTERIOR SURFACES AND FEATURES: BEDROOM CLOSET CEILING IS IN DISREPAIR, EVIDENCED BY CEILING SURFACE HAS BUBBLED & IS PEELING. T.C. SEC. 16-12 (A) EXTERIOR SURFACES/WEATHER PROTECTION, DILAPIDATED STRUCTURES: (1) 2-HOLES APPROX 4''X12'' BY HOT WATER HEATER LACKING GRILL. (2) WOOD FASCIA IN DETERIORATED STATE EVIDENCED BY WOOD ROT HAS SET IN & FASCIA COMING AWAY FROM STRUCTURE. |
|
08/23/2004 | INSP - INITIAL CODE ENFORCMENT | Correction Required | VISITED SITE MADE CONTACT WITH TENANT, TENANT STATED SHE HAS OCCUPIED APT SINCE 6/04. TENANT STATED THERE IS SEVERAL MIN HOUSING VILATIONS THROUGHOUT 7 STRUCTURES COMPLEX. TENANT STATED MADERA REALTY HAS REMOVED ITSELF FROM MANAGING PROPERTY DUE TO OWNER UNWILLINGNESS TO REPAIR AND MAINTAIN ALL STRUCTURES, BACK YARD IS BEING USED AS STORAGE FOR DISABLED VEHICLES, 3 TRUCKS AND 2 VEHICLES. SEVERAL MISC. ITEMS SUCH AS OLD TABLES, FENCE SECTION (WOODEN) CARPETING, METAL SHELVING, TIRES AND METAL TUBING. ENTERED STRUCTURE ADDRESS 2928 B, VIOLATION ARE AS FOLLOWS: WEATHER PROOFING 1. NEW ENTRY DOOR INSTALLED AND LACKING CASING. 2. BROKEN WINDOW THROUGHOUT STRUCTURE - PEST CONTROL. 3. TERMITE DAMAGE AT BEAM CEILING AND MUD TUNNELS ON WALL BY WINDOW ELECTRICAL. 4. ADDITION OF ELECTRICAL CONDUCTOR FOR CEILING FAN IN KTICHEN NOT IN CONDUIT. EXPOSED ELECTRICAL CONDUCTORS EXTENDING FROM CEILING IN SOUTH BEDROOM. NOTE - CONDUCTORS ABOVE 7 FOOT AND OUT OF REACH. NO CHILDREN IN UNIT, TENANT LIVES ALONE. 5. BATHROOM FIXTURE 2-PRONG PLUMBING 1. POSSIBLE W/O/P ADDITION OF WATER LINES IN BATHROOM. 2. EVIDENCE OF GAS PIPING ADDITION AND ALTERATION NOT SECURED TO WALL PROPERLY, THROUGHOUT ALL STRUCTURES. ELECTRICAL 1. ORIGINAL 60 AMP SERVICE DISCONNECT WIRING HAS BEEN ALTERED EVIDENCED BY ILLEGALLY SPLICED CONDUCTOR IN DISCONNECT BOX. ELECTRICAL UPGRADE HAS BEEN DONE FOR COMPLEX AND NEXT DOOR APT. ADDRESSED 2928A ORINGIAL 60 AMP SERVICE IS IN A DETERIORATED AND DILAPIDATED STATE, EVIDENCED BY OUT DATE DISCONNECT BOX CONDUIT ATTACHED AT BOTTOM IS NOT WEATHER PROOF FITTING. |
Showing 1 to 6 of 6 entries