Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/15/2004 | INSP - INITIAL CODE ENFORCMENT | Correction Required | INSPECTION MAIN STRUCTURE: SECURED BEING USED AS STORAGE, NO ONE LIVING IN IT. ELECTRICAL METER X50898, ONE WATER METER FOR (2) STRUCTURES. (2) FRONT PLATE MISSING OUTSIDE COVER NOT SECURED. ELECTRICAL CONDUCTORS BRITTLE. FASCIA NEEDS PAINTING. ROOF NEEDS TO BE REPLACED, SHINGLES MISSING WOOD DETERIORATED. TRASH AND DEBRIS BEHIND MAIN STRUCTURE. FENCE DETERIORATED AND LEANING. PORCH (1) 4 X 4 SUPPORTED BY A BRICK ON BOTTOM ALSO WITH A 2 X 6 LEANING TO SUPPORT PORCH, ALL NEEDS PAINTING. PORCH ADDED NO SUPPORT POSTS OVERHANGINGS 5'. SECOND STRUCTURE IS ON 50 AMP SERVICE. INTERIOR BACK ROOM: HOT PLATE (ELECTRICAL) WITH POWER STRIP, NO GAS SUPPLY TO UNIT. KITCHEN OUTLET NO GFI PROTECTED NO CAP ON FEED FOR GAS. NO POWER TO BEDROOM AND KITCHEN AND BATHROOM. 20 AMP CIRCUIT RECONNECT, POWER TO BACKROOMS. BEDROOM: WIRES SPLICED FOR LIGHTING. HAS MULTIPLE EXTENSIONS CORDS SPLICED IN ILLEGALLY FOR LIGHTING AND TO POWER. NO PERMIT SECURED FOR HEATING OR COOLING, NO EGREES IN BEDROOM. APPLIANCE CORDS FOR PERMANENT WIRING. EXPOSED WIRING ON WALL. REVERSE HOT/NEUTRAL IN BEDROOM NORTH WALL. BATHROOM: HOT PLATE HEATING WATER, ILLEGALL SPLICED CONDUCTOR TO SUPPLY HOT H2O FOR SHOWER WITH WATER HOSE. TENANT HAS TO SIPHON HOSE FOR HOTWATER. NO SHOWER HEAD ON GOOSE NECK. MADE JOHN TENANT CAP HAZARDOUS WIRING, AND CAP HAZARDS AS PER INSPECTORS. IMMEDIATE HAZARDOUS ELLIMINATED WHILE ON SITE. ELECTRICAL CONTRACTOR NEEDS TO ASSESS ELECTRICITY. 2ND STRUCTURE NORTHSIDE BOOTED IN WITH PLYWOOD AND SCREEN, FASCIA DETERIORATED AND MISSING, APPROXIMATELY 30' TO 40' BOOTED IN AZ ROOM. WOOD SPLINTERING PAINT NEEDED AZ ROOM INSIDE 2 X 4'S OVER SPAN TO 10' NO TIES AND HAS BEEN CONSTRUCTED IN A HAZARDOUS MANNER. SEVERAL CIRCUITS ADDED IN HAZARDOUS MANNER, OPEN CIRCUITS, ROMEX NOT PROPERLY ANCHORED, NO CONDUIT. BOXES NOT WEATHER PROOF, FLOORING IS EXPOSED WOOD. DEN/KITCHEN MICROWAVE AND REFRIGERATOR EXPOSED ROMEX FOR LIGHT SWITCH DOES NOT WORK. ELECTRIC SUPPLIED FROM OTHER ROOM FOR MICROWAVE AND REFRIGERATOR AND LIGTHING. NO EGRESS IN DEN/KITCHEN MIGHT HAVE BEEN A CARPORT. CLOSET IN ARIZONA ROOM: EXPOSED CIRCUITS, NO CONDUIT NO COVER PLATES. SUB PANEL ON 2ND STRUCTURE WIRE MIGHT BE WRONG SIZE, MISSING DEAD PLATE INCORRECT WIRE GAUGE TO BREAKER, POSIBLE HOLE SUBPANEL BOOTED IN. 2ND STRUCTURE OPEN DRAIN, NO CAP. WATER HOSE FOR SHOWER. HOT WATER HEATER DOES NOT WORK, NOT CONNECTED TO GAS LINE, NO GAS/LACKING TPR FOR DRAIN, CEILING FOR HOT WATER CLOSET DETERIORATED, WOOD ROTTING. WASHING MACHINE UNDER PORCH NOT PEE-TRAP. PORCH - 12 X 6 LEANING, FASCIA NEEDS TO BE REPLACED. ROMEX UNDER PORCH NOT IN CONDUIT HAZARDOUS CONDITIONS ILLEGAL CIRCUITS. |