Case: T04DV00520

Parcel: 134071830


Addresses:

8435 E KENYON DR

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
02/14/2005 INSP - FOLLOW UP CODE ENFORCE Approved AT SITE, SMOKE DETECTORS INSTALLED IN ALL ROOMS. NO PERMITS ON RECORD WITH D.S.D. FOR REQUIRED NEWLY INSTALLED FURNACE, A/C UNIT, HOT WATER HEATER. MULTIPLE VIOLATIONS IN SUB PANEL.
MAIN SERVICE PANEL:
DOUBLE LUGGING ON LINE SIDE AND ON LAND SIDE, TAPPING FROM METER SIDE, 2 SERVICE DISCONNECTS. BREAKER NEEDS TO FEED SUB PANEL.
DOUBLE LUGGING ON LAND SIDE, NOT PROPER OVER CURRENT PROTECTION. 20 AMP RATED CONDUCTORS ON 100 AMP MAIN BREAKER.
1ST SUB PANEL:
ILLEGAL FEED COMING FROM DOUBLE LUGGING ON MAIN SERVICE.
2ND SUB PANEL:
ILLEGAL FEED COMING FROM DOUBLE LUGGING ON MAIN SERVICE. INPROPER OVER CURRENT PROTECTION. IMPROPER FUSING.
DOUBLE LUGGING ON NEUTRAL, INCLUDING EQUIPMENT GROUNDING CONDUCTOR.
01/05/2005 INSP - FOLLOW UP CODE ENFORCE Approved AT SITE NO ONE HOME, CALLED JIAREME SERVENTTI WITH AL BROKERS. HE WILL CONTACT TENANT TO SCHEDULE RE-INSPECTION TIME WITH TENANTS.
09/22/2004 INSP - FOLLOW UP CODE ENFORCE Correction Required NOV SENT TO ALL BROKERS.
09/21/2004 INSP - FOLLOW UP CODE ENFORCE Correction Required ALL MAIL CAME BACK. WENT TO POST NOTICE ON UNIT AND TENANT INFORMED ME OF NEW OWNERS AND THEIR ADDRESS. WILL SEND NOTICE OUT TO ALL BROKERS INC.
08/16/2004 INSP - FOLLOW UP CODE ENFORCE Correction Required NOV OUT.