Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T04DV00422

Parcel: 120061310


Addresses:

419 E LINCOLN ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
05/21/2004 INSP - INITIAL CODE ENFORCMENT Approved EXTERIOR ADDITION OF GAS PIPING & WATER LINES. SEPERATE PANELS FOR 419-A&419-B (419-A MISSING BREAKER BLANK OFF. 1-20 AMP BRAKER DOUBLE LUGGED, ADDITION OF 220 CIRCUIT, 60 AMP CIRCUIT CONNECTED TO BUS BAR (ELECTRICAL CONDUCTOR) HAS MELTED INSULATION AND IS DISCOLORED. PANELS NOT MARKED. ADDITION OF ELECTRICAL CIRCUIT FOR EXTERIOR LIGHTING FOR PORCH & BY ENTRY DOOR & SHRINE ARE NOT IN CONDUIT. EXTERIOR RECEPTACLES LACKING WEATHER PROTECTION. ADDITION OF DRAIN FOR WASHING MACHINE LACKING P-TRAP & IS EVIDENCED OF W/O/P, NORTH PORCH AREA 220 RECEPTACLE LACKING WEATHER PROOF COVER. WEST WALL AT ROOF LINE (ELECTRICAL CONDUCTORS) ARE WIRE NUTTED & NOT IN JUNCTION BOX. TERMITE DAMAGE AT NORTHWEST CORNER OF LAUNDRY ROOM. BROKEN WINDOW AT LAUNDRY & WEST BEDROOM. EGRESS FROM BEDROOM ON EASTSIDE HAS WROUGHT IRON, NO QUICK DISCONNECT FOR FIRE & OR PANIC. 2ND HOUSE AT BREAKER PANEL DOUBLE LUGGED & ADDITION OF CIRCUIT (NO POWER) RUNS TO BACK OF STRUCTURE. WROUGHT IRON DOOR ON MAIN STRUCTURE ILLEGAL SECURITY LATCHS & LAUNDRY ROOM. TENANT STATES PROBLEM WITH COOLERS, WHEN BOTH ON BREAKER TIPS.
KITCHEN 1-2 PRONG RECEPTACLE, OPEN GANG BOX ON NORTH WALL. 220 CONNECTION BEHIND ELECTRICAL STOVE HAS UNPROTECTED WIRES DOUBLE KEYED DEAD BOLT AT FRONT DOOR. EVIDENCE OF ADDITION W/O/P COMPUTOR ROOM HAS WINDOW PANES THAT OPEN INTO COMPUTER ROOM. MIDDLE BEDROOM WEST WALL BEHIND DOOR HAS TERMITE DAMAGE APPROX 3' LONG, EXPOSED DOUBLE GANG BOX SWITCH LACKING COVER PLATE. WALL BY WINDOW SHOWS WATER DAMAGE & WROUGHT IRON BARS HAVE NO SECURITY BAR RELEASE. BEDROOM HAS FURNACE ENCLOSURE MAY BE ILLEGAL & LACKING DOOR, ALSO HAS SHUT OFF PANEL ON OPPOSITE WALL. MIDDLE WEST BEDROOM LACKS SWITCH PLATE COVERS. LIGHT FIXTURE CEILING LACKING LIGHTGLOBE. REVERSE NEUTRAL FOUND IN BEROOMS RECEPTACLES & LACKING COVER PLATES. BEDROOM SINK PLUMBING NOT WORKING. POSSIBLE VENT CLOSED OFF WITH TAPE & FOIL. NORTHWEST BEDROOM WINDOW CRANK NOT WORKING & WROUGHT IRON ENCLOSURE LACKING QUICK RELEASE. EVIDENCE OF TERMITE DAMAGE ON WEST WALL. NORTH LAUNDRY APPEARS TO BE ADDITION APPROX 12'X30' EXPOSED ELECTRICAL CONDUCTOR FOR LIGHT SWITCH. VENT PIPE MAY BE ILLEGALLY INSTALLED (ABS) EXTENDS THROUGH ROOF. ALL LAUNDRY ROOM PLUMBING LACKING HARDWARE FOR ATTACHING TO WALL. TPR DRAIN HOSE DO NOT MEET CODE. GAS PIPING HAS BEEN ALTERED IN LAUNDRY ROOM (LAUNDRY ROOM ATTACHED TO MAIN STRUCTURE). MAIN BATH ROOM LAVE SINK IS DETERIORATED & HAS APPROX 3/4 WIDE BY 3' LONG HOLE, WATER LEAKING FROM TOILET TANK CONNECTION. EXPOSED ELECTRICAL WIRE EXTENDING FROM TILE & SHOWER DOOR WILL NOT OPERATE PROPERLY. TILE NEEDS GOOD CLEANING & HAS NOT BEEN MAINTAINED.NO G.F.C.I. IN KITCHEN & BATH ROOMS. OPEN GROUNDS IN BEDROOMS & 2 PRONG RECEPTACLES IN MASTER BATH ROOM. 6'8' CEILING IN BATH ROOM & BEDROOM (MASTER). SMOKE DETECTOR LACKING THROUGHOUT STRUCTURE. HALLWAY TO MASTER BEDROOM IS LACKING FINISH, TENANT INSTALLED DRYWALL PATCH.