Case: T04DV00143

Parcel: 123121550


Addresses:

2365 N VINE AV


Inspection Status: Correction Required

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Case Number - T04DV00143

Inspection Description - INSP - FOLLOW UP CODE ENFORCE

Inspection Status - Correction Required

Date Description Inspector Results Comments
03/10/2004 INSP - FOLLOW UP CODE ENFORCE Correction Required FIRST THING IN THE MORNING INSPECTOR CAMACHO IS INFORMED BY CECI CRUZ STRUCTURE IS NOT SECURED. INSPECTOR CAMACHO THEN CONTACTS MATT BATHCREST SUPERVISOR. MATT STATES MIKE SHOULD BE ON SITE AS OF 6:30 THIS MORNING. INSPECTOR CAMACHO ARRIVES ON SITE TO FIND MIKE AND ENTIRE CREW (4) FINISHING UP BOARD UP. (SEE PICTURES). BOARD UP 100% COMPLETE. INSPECTOR CAMACHO CONTACTS RICK S. WITH NEW STATUS.
03/09/2004 INSP - FOLLOW UP CODE ENFORCE Correction Required FOLLOW UP INSPECTION FOUND STRUCTURE IN SAME CONDITION. INSPECTOR HAS NOT HAD ANY CONTACT WITH OWNER OR HEARD FROM OWNER. CONTACTED RICK S. WITH FINDINGS. DECISION REACHED TO ORDER STRUCTURE SECURED. CONTACTED BATHCREST WHILE ON SITE. ASSISTED BY INSPECTOR HURD. BATHRCREST WILL CONTACT INSPECTOR WHEN THEY ARE TO ARRIVE ON SITE.
MET ON SITE WITH BATHCREST LATER IN THE DAY.MET WITH MIKE FOR INSTRUCTIONS ON BOARD UP. STRUCTURE MUST BE 100% BOARDED BOTH FLOORS ALL EXTERIOR WINDOWS AND GARAGE WINDOW. MIKE WOULD LIKE TO SECURE ENTIRE BOTTOM STORY TODAY AND RETURN FIRST THING IN THE MORNING TOMORROW TO COMPLETE TOP FLOOR WINDOWS. DUE TO THE FACT HE ARRIVED ALONE AND DID NOT HAVE ASSISTANCE NEEDED FOR TOP WINDOWS. ALSO LATE IN THE DAY. INSPECTOR CAMACHO FELT THIS WOULD BE ACCEPTABLE. ATTEMPTED TO CONTACT RICK S WHILE ON SITE. LEFT VOICE MESSAGE WITH STATUS.
WHILE IN ROUTE BACK TO OFFICE RECEIVED A CALL FROM RICK S. HE STATED STRUCTURE MUST BE 100% SECURED BY THE END OF THE DAY. INSPECTOR CAMACHO WOULD THEN ATTEMPT TO CONTACT MIKE WITH BATHCREST (267 -6900) NOT ABLE TO CONTACT HIM DUE TO PHONE BATTERY DEAD. INSPECTOR WOULD CONTINUE TO OFFICE TO DROP OFF INSPECTOR HURD AND THEN RETURN TO SITE.
WHILE BACK AT SITE INSPECTOR INFORMED MIKE WITH BATHCREST STRUCTURE MUST BE 100% SECURED BY THE END OF THE DAY. MIKE THEN CONTACTED ASSISTANCE WITH ORDERS TO BRING LIGHTS IN CASE SECUREMENT RAN LATE INTO NIGHT. MIKE WOULD CONTACT INSPECTOR CAMACHO WHEN BOARD UP WAS COMPLETE 100%.
INSPECTOR CAMACHO RECIEVED A CALL FROM MIKE STATING BOARD UP WAS COMPLETE. INSPECTOR THEN CONTACTED RICK S WITH STATUS.
03/08/2004 INSP - FOLLOW UP CODE ENFORCE Correction Required FOUND STRUCTURE HAS OSB 1/2" PLYWOOD ON NORTH EXTERIOR WINDOWS. FOUND 1/2" SHEETROCK INSTALLED TO INTERIOR OF EXTERIOR WEST WALL WINDOWS. THIS IS NOT AN ACCEPTABLE MEANS OF SECUREMENT. FOUND SOUTH EXTERIOR WINDOWS SECURED WITH 1/8 PANELING. THIS ALSO IS NOT AN ACCEPTABLE MEANS OF SECUREMENT. FOUND FRONT EAST EXTERIOR WINDOWS WITH 1/2 " CDX PLYWOOD SCREWED TO WINDOW FRAMES. FOUND ALL TOP STORY WINDOWS HAVE BLUE TARPS NAILED TO THE INTERIOR FRAMES OF ALL WINDOWS. NOT ACCEPTABLE MEANS OF SECUREMENT. FOUND GARAGE WINDOW AT NORTH END OF GARAGE NOT SECURED. NO WORK HAS BEEN DONE TO ANY OF THE YARD AREAS. FOUND WEEDS, JUNK AND DEBRIS THROUGHOUT ALL YARD AREAS. LEFT VOICE MESSAGE WITH OWNER TO CONTACT INSPECTOR BY THE END OF THE DAY OR THE CITY OF TUCSON WILL TAKE ACTION TO SECURE PROPERTY CORRECTLY. ALSO INCLUDED IN VOICE MESSAGE YARD AREAS MUST BE CLEARED OF ALL WEEDS, JUNK AND DEBRIS. (SEE PICTURES).