Inspection Status: Compliance
Inspection History: INSP - FOLLOW UP CODE ENFORCE
Case Number - T04DV00082
Inspection Description - INSP - FOLLOW UP CODE ENFORCE
Inspection Status - Compliance
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/18/2004 | INSP - FOLLOW UP CODE ENFORCE | Compliance | FULLY ABATED. PERMITS WERE PULLED FINALIZED INSPECTED AND PASSED. OKAY TO CLOSE CASE. | |
02/13/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | TENANT WAS NOT AT SITE FOR (UNIT 604). I DID SPEAK TO MANAGER AT SITE SHE STATED IT WAS REPAIRED A FEW DAYS AGO. I DID SPEAK TO MAINT. AT SITE IT WAS A HW HEATER IN THE ABOVE UNIT 614 WORK ORDER #3369-CASE WILL BE ADDED TO SABER CASE. THE HOT WATER HEATER VALVE BROKE ON HEATER. BURN'S SPRAYS FOR INSECTS TWO TIMES A MONTH. UNIT WILL BE SPRAYED AGAIN IN 2 WEEKS. OKAY NOT TO RETURN TO UNIT 604. SPRAY COPY WITH CASE FILE DRIP WAS IN HALLWAY MANAGER DID DRY. TENANT MOVING 03/10/04. | |
02/06/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | TODAY WAS THE DAY THAT APT. OWNER WOULD HAVE ALL METERS UP AND RUNNING, (WITH ELECT ON) AN INSPECTION WAS DONE TODAY AND THE FOLLOWING WAS FOUND, OWNER HAS INSTALLED A FULLY NEW SYSTEM ON THE WEST SIDE OF BUILDING 500, THIS IS A TOTAL AMP SYSTEM OF 1600. THERE IS (8) NEW METER PACKS INSTALLED SHOWING 200 AMPS EACH. PERMIT WAS PULLED BY CONTRACTOR (BLACK HAWK ELECT) #T04EL00163, PERMIT WAS PULLED JAN. 27, 2004. PERMIT WAS FINAL ON FEB. 6TH, 2004. IN THE INSPECTION SCREENS, PENDING DATA ENTRY FROM DSD ON BASE SCREEN, AND ALL CLEAR WAS SENT VIA FAX TODAY BY DSD TO OK TURN ON OF ALL (8) METERS AROUND 3:00 PM. THE SYSTEM REMAINS OFF. THE MANAGER WANTS THE COT TO PLACE TENANTS UNTIL TEP RESTORES POWER. MANAGER IS AWARE THAT UNITS REMAIN UNSAFE TO LIVE IN AND NOTICE OF VIOLATION STANDS. FOLLOW UP MONDAY FEB 9, 2004. NEW PHOTOS WERE TAKEN OF SYSTEM. | |
02/03/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | AT SITE I DID REVIEW CURRENT ISSUE'S, AT THIS TIME THERE ARE NO CHANGES AND ALL UNITS REMAIN EMPTY AND SECURED. FOLLOW-UP IN 3 DAYS WITH CONTRACTOR. | |
01/29/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | REVIEW WAS DONE WITH CONTRACTOR( BLACK HAWK). AT SITE THE FOLLOWING ISSUES WERE FOUND. PER THE SALESPERSON THE SYSTEM HAS BEEN TAMPERED WITH TRYING TO JUMP METERS, AND DAMAGE WAS DONE TO THE TRANSFORMER AND THE ENTIRE 8 PACK OF METERS AT BUILDING 500. |