| 05/26/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 5/26/04, REVISITED SITE, TOOK PICTURES, MET WITH OWNER PAUL ON SIGHT, 3 OF THE 4 MOBILE HOMES HAS BEEN REMOVED FROM PROPERTY 4TH ONE HAS BEEN DISCONNECTED AND IS HOOK UP TO MOVING TRUCK, WAITING TO BE PULLED OFF PROPERTY, MAIN GAS METER FOR REAR HAS BEEN REMOVED, ALL ELECTRIC HAS BEEN DISCONNECTED, T.E.P. DROP TO METERS WILL BE REMOVED BY T.E.P BY WED. 6/2, ALL VIOLATIONS CONCERNING UNIT C, UNIT D, UNIT E, UNIT F, HAS BEEN ABATED DUE TO REMOVING ALL MOBILE HOMES FROM PROPERTY. VIOLATIONS LEFT AT THIS TIME WILL BE CONCERNING FRONT MAIN HOUSE, STILL NEEDING TO SECURE PERMITS FOR WORK AND ADDITION TO MAIN HOUSE, HASN'T DONE THIS YET DUE TO NEEDING $480.00 COST OF PERMITS, HAS BEEN PUTTING ALL HIS MONEY INTO REMOVING MOBILE HOMES, ALSO PAUL SOLD ANOTHER HOUSE HE OWNED TO MAKE UP MONIES, IT DID SELL AND HE SIGNED PAPERS TODAY AND SHOULD BE COLLECTING HIS MONEY, STATED TO ME HE WOULD BE GOING DOWN TO D.S.D. ON TUESDAY 6/1 AND GET PERMITS STARTED. GRANTED EXTENSION. DUE TO MOVING FORWARD WITH ABATEMENTS, AND KEEPING IN CONTACT WITH ME. FOLLOW UP 30 DAYS | |
| 03/19/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 3/18/04, REVISITED SITE, TOOK PICTURES, MET WITH OWNER PAUL WATTERS ON SITE, WALKED ALL UNITS, UNIT A, WHATS NOT COMPLETED, (1) T.C. 16-11 C (1)-ELECTRICAL SYSTEM NUMBER 1, ON NOTICE AND ORDER. NOT DONE, ALSO NO PERMITS SECURED, (2) T.C.16-11 C (1) ELECTRICAL SYSTEM: NUMBER 8 ON NOTICE AND ORDER, HAS NOT SECURED PERMITS. UNIT A, T.C. 16-11 E (3,4,5) PLUMBING SYSTEM: ALL WORK COMPLETED, NEEDS TO SECURE PERMIT FOR REMOVAL OF GAS LINES. UNIT A, T.C. 16-11 D MECHANICAL EQUIPMENT, OWNER MOVED HOT WATER TANK TO EXTERIOR, DID NOT SECURE PERMITS. UNIT A, T.C. 16-4 PERMITS REQUIRED, HAS NOT SECURED PERMIT FOR ADDITION TO REAR OF STRUCTURE. NEEDS TO SECURE PERMIT FOR INSTALLATION OF A/C HEAT PACK ON ROOF. UNIT C. NOTHING HAS BEEN DONE ON THIS MOBILE HOME: THIS MOBILE HOME HAS BEEN VACATED AT THIS TIME, IS NOT TO BE RERENTED UNTIL ISSUES HAS BEEN ABATED, PAUL AGREED. UNIT D: T.C. 16-11 E (5) PLUMBING SYSTEM: OWNER HAS MADE REPAIRS TO GAS LINE, DID NOT SECURE PERMIT. REST OF UNIT D COMPLETED. UNIT E: 3/18/04, DONE SHUT DOWN ON UNIT, NOTHING DONE FROM NOTICE AND ORDER, TO THIS UNIT DUE TO OWNER WAS IN PROCESS OF EVICTING, RESIDENT CAME UP WITH RENT MONEY STILL OCCUPING UNIT. DONE EMERGENCY SHUT DOWN ON UNIT DUE TO LACK OF ELECTRICAL POWER, WAS USING A 15 AMP EXTENSION CORD TO SUPPLY ELECTRICAL POWER FROM NEIGHBORS ELECTRICAL PEDSTAL. POSTED 0 DAYS TO DISCONNECT EXTENSION CORD NOT TO REOCCUPY UNTIL ELECTRICAL UTILITY HAS BEEN PROPERLY RESTORED. UNIT F: NOTHING HAS BEEN ABATED ON THIS UNIT, OWNER IS MOVING RESIDENTS INTO UNIT A, AND WILL BE REMOVING UNIT F, FROM PROPERTY DUE TO EXTENSIVE REPAIRS. COMMOM AREA MAIN ELECTRICAL: NO WORK DONE TO ELECTRIC SYSTEM, PAUL STATED HE IS TRYING TO GET 3,500.00 FOR REPAIRS, HAS NOT SECURED PERMIT. PAUL STATED HE WILL BE GOING TO DEVELOPMENT SERVICES ON MONDAY TO START ON SECURING OF ALL PERMITS. PAUL ASK FOR MORE TIME, HE HAS MAKE PROGRESS ON PROPERTY, GRANTED 30 DAY EXTENSION. FOLLOW UP APRIL 19, 2004. |
|
| 02/10/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT D 2/9/04, REVISITED SITE, MET WITH OWNER PAUL WATTERS, PAUL DID ASK IF I COULD COME BY AND DO INSPECTION ON UNIT D SO HE COULD RERENT THIS UNIT. DOES NOW HAVE ELECTRIC AND GAS ON TO DO FULL INSP. DID GO AND DO INSP. FOUND NOTHING AT THIS TIME TO HOLD BACK UNIT, ALL ELECTRIC READS FIND UNDER TEST, REMOVED COVER TO SUB-PANEL NO DOUBLING LUGGING, LOOKS OK INSIDE AT THIS TIME, HEATER WORKING FINE, STOVE AND REFRIG. WORKING FINE, KITCHEN AND BATH GFCI PROTECTED, HOT AND COLD RUNNING WATER, DID FIND THAT WINDOWS HAS BEEN REPLACED AND BEDROOM WINDOWS DO NOT MEET EGRESS CODE, TALKED TO PAUL ABOUT THIS PAUL ASSURED ME HE WOULD MAKE CORRECTIONS WITH IN A WEEK, ALSO FOUND EXTERIOR GAS LINE HAS BEEN DAMAGED AND WILL NEED TO BE REPLACED, ALSO NEEDS TO INSTALL A.G.A. APPROVED GAS VALVE, TALKED WITH OWNER PAUL AND AGAIN PAUL STATED THAT HE WOULD MAKE REPAIRS, EXPLAINED TO PAUL WOULD NEED TO SECURE A PERMIT FROM D.S.D. TO DO THIS WORK. HE WILL SECURE A PERMIT, ALSO NEEDS TO INSTALL A EMERGENCY WATER SHUT OFF VALVE FOR THE HOT WATER TANK, AGAIN PAUL STATED HE WOULD REPAIR UNDER PERMIT, AS TALKING WITH PAUL WE WENT OVER ALL ISSUES ON N/O, PAUL EXPLAINED THAT HE WOULD BE GOING TO COURT ON FRIDAY 2/13/04 TO EVICT RESIDENTS IN UNIT A, ALSO UNIT E, WHEN EVICTION IS DONE THE RESIDENTS WHO NOW RESIDES IN UNIT F WILL BE MOVING INTO UNIT A AND PAUL WILL BE MOVING UNIT F OFF PROPERTY, AND WILL RELOCATE UNIT C IN WHERE UNIT F WAS, WILL SECURE STATE PERMIT FOR RECONNECTION. |
|
| 01/29/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 1/27 04, REVISITED SITE FOR INSPECTION OF TRAILER F: INTERIOR: INSPECTION FOUND SEVERAL MIN. HOUSING ISSUES, HAS ROACH INFESTION, KITCHEN SINK FAUCET LEAKS AT FIXTURE, KITCHEN CABINET DOORS OFF HINGES AND OR ARE MISSING, KITCHEN CONVENIENCE OUTLET BY MICROWAVE HAS REVERSED POLARITY IN ELECTRICAL SYSTEM, KITCHEN FLOOR COVERINGS COMMING UP AND PEELING, CRACKED, PARTS OF TILING MISSING, LIVING ROOM HAS BROKEN WINDOW TAPED UP, LIVING ROOM CEILING IS FALLING IN PLACES, HAS DRYWALL INSTALLED NOT FINISHED, NOT TAPED OR SEALED, NO PAINT OR OTHER SEALANT, A/C INSTALLED ON NORTH WALL HAS LEAKED DOWN WALL AND INSIDE WALL, LIVING ROOM FLOOR IN WEAK AND SPONGY ALONG SOUTH WALL AND AROUND FLOOR REGISTER, COOLER SWITCH HAS BEEN RELOCATED AND WIRING HAS BEEN INSTALLED AND RELOCATED, (RESEARCH PERMIT) LIVING ROOM LIGHT FIXTURE, HAS EXPOSED WIRING, FORCED AIR HEATER HAS EXPOSED THERMO-STAT WIRING AND HANGING IN CLOSET, T-STAT HAS BEEN INSTALLED IN CLOSET, (WRONG INSTALLATION), HEATER IS NOT OPERATING PROPERLY HAVE TO OPEN UP HEATER GO INSIDE AND PLUG IN FORCED AIR FAN TO MAKE WORK AND THEN GO BACK AND UNPLUG TO STOP FAN FROM WORKING, HEATER LACKS CLEANING MAINTENANCE, DWELLING LACKS SMOKE DETECTORS, BATHROOM HAS ELECTRICAL LIGHT SWITCH HANGING FROM WALL, NOT SECURED, LIGHT SWITCH HAS EXPOSED WIRING, AND NO COVER PLATE INSTALLED, BATH VANITY NOT SECURED TO WALL, LOOSE, WALL ON WEST SIDE CAN ALMOST PUSH WALL DOWN WALL NOT STABLE AT ALL, SHOWER AREA HAS HAD FLOOR VYNIL INSTALLED AROUND WALLS HAS HOLES, NOT PROPECTING WALL STRUCTURE FROM WATER, TIOLET KEEPS RUNNING, CAULKING IN BATH BAD EVERY WHERE, REAR DOOR WEATHER STRIPPING BAD AND OR MISSING, HAS 2 LOCKING HASPS ON INTERIOR, CREATING EGRESS PROBLEM, LIGHT SWITCH IN BED ROOM HANGING FROM WALL, EXPOSED WIRING, |
|
| 01/29/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 1/27/04, VISITED SITE TO DO INSPECTION ON TRAILER F, INSPECTOR CAMACHO ASST. WITH INSPECTION, WHILE ON SITE FOUND TRAILER C- SUPPLYING POWER TO FRONT UNIT BY EXTENSION CORD, WENT TO TRAILER C AND EXPLAINED TO RESIDENT THAT THIS IS ILLEGAL AND WOULD HAVE TO BE DISCONNECTED, RESIDENT STATED THAT LET RESIDENT IN FRONT UNIT KNOW IT WILL BE DISCONNECTED, IEXPLAINED I WOULD DO THAT BECAUSE I WOULD BE DISCONNECTING ANY WAY AND THAT IF DONE AGAIN COULD HAVE HER ELECTRIC DISCONNECTED RESIDENT STATED HER ELECTRIC HAS ALL READY BEEN TRANSFERED DUE TO SHE IS MOVING OUT, WENT TO FRONT UNIT AND TALKED WITH MICHELLE AND EXPLAINED TO HER THAT THIS IS ILLEGAL AND I WOULD HAVE TO DISCONNECT AND ALSO WOULD BE SHUTTING DOWN HER UNIT, AND DOING THIS SHE WOULD NOT BE ABLE TO STAY THERE UNTIL ELECTRICAL UTILITIES HAS BEEN RESTORED, I ASKED MICHELLE IF SHE HAD ANOTHER PLACE TO STAY UNTIL ELECTRIC SERVICE HAS BEEN RESTORED AND MICHELLE STATED YES SHE COULD STAY WITH A FRIEN, I EXPLAINED TO MICHELLE THAT SHE COULD COME AROUND AND CHECK ON HER PERSONAL BELONGINGS BUT COULD NOT BE HANGING AROUND THERE AND COULD NOT STAY AT NIGHT THERE SHE STATED SHE UNDER STOOD, DISCONNECTED ELECTRICAL EXTENSION CORD AND POSTED UNIT UNFIT TO OCCUPY. PICTURES IN FILE. | |
| 01/26/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 1/15/04, REVISITED SITE FOR INSPECTION OF RENTALS ON SITE, STARTED WITH TRAILER (C), INTERIOR: WEST END OF TRAILER, BEDROOM, WINDOWS ARE OF LUVERED TYPE, DO WORK, CONVENIENCE OUTLETS THROUGH OUT TRAILER ARE OF 3 PRONG TYPE, SHOWS OPEN GROUND UNDER TEST, HEATER IN LIVING ROOM HAS CAUTION TAPE ON FRONT COVER DUE TO THE FRONT METAL COVER PANEL FALLS OFF WILL NOT STAY IN PLACE, LIGHT FIXTURES MISSING COVERS, KITCHEN CONVENIENCE OUTLET SHOWS OPEN GROUND AND NOT GFCI PROTECTED, UNDER KITCHEN SINK CABINET THERE IS HOLE THAT GOES ALL THE WAY THROUGH TO THE OUTSIDE, RESIDENT HAS STUFFED WITH RAGS TO PREVENT ANY THING FROM CLIMBING IN AND TO HELP BLOCK WIND, BATH ROOM WINDOW HAS BEEN REPLACED WITH A PIECE OF PLEXI-GLASS, NO VENTALITION, BATH LIGHT FIXTURE HAS 3 PRONG PLUG NOT GFCI PROTECTED, BEDROOM AT EAST END HAS DOOR NAILED CLOSED, NO EGRESS, RESIDENT STATED WILL BE MOVING OUT OVER THE WEEK END WILL BE OUT ON MONDAY, MOVING DUE TO ALL THE HAZARDS AROUND THE PROPERTY, NEIGHBORS, SHOOTINGS, GUNS, TRAILER (D) INTERIOR TRAILER D IS VACANT AT THIS TIME, RESIDENTS VACATED DUE TO STAND OFF WITH POLICE, DID WALK TRAILER D, BUT ELECTRICITY HAS BEEN TURNED OFF, COULD NOT SEE MUCH OR TEST, TRAILER (E) INTERIOR: TRAILER E IS A SMALL TRAVEL TRAILER 8'X22' IS ALSO A RENTAL, DID INSPECTION IN TRAILER, CLUTTERED WITH TRASH AND DEBRIS, NO SMOKE ALARM, REAR DOOR IN BEDROOM HAS TRASH AND DEBRIS CAN NOT USE FOR EGRESS, RESIDENT SAYS EVERY THING WORKS, COULD NOT MUCH DUE TO ALL THE DEBRIS INSIDE, TRAILER (F) NOT HOME WILL DO INSP. ON FRIDAY 1/16. 1/16/04, COULD NOT MAKE APPT. DUE TO ANOTHER INSPECTION, CALLED AND RESCHEDULED FOR TUESDAY 1/27/04. |