Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM05624

Parcel: 111072930


Addresses:

3108 E TOWNER ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/21/2005 FRAMING Approved IVRS - Inspection :*
1) REINSPECT DELETION OF 2 SOUTH WINDOWS ON APPROVED PLAN VERIFIED
04/07/2005 FRAMING Partial Approval IVRS - Inspection :* PARTIAL OK PENDING DELETION OF 2 SOUTH WINDOWS
04/05/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) H2.5 EVERY HOLE NAILS CEILING JOISTS SOUTH WALL
2) BLOCK MECHANICAL REFORM 3 SIDES
3) BLOCK BATH REGISTER 3 SIDES
4) FIRESTOP ALL AREAS MARKED
5) BLOCK UNDER FRONT PORCH LEDGER FASTEN 6" ON CENTER
6) STRAP AND SHIM ALL HEADERS
7) MISSING STUD REFRIG. WALL
8) DAMAGE PLATE SOUTH BATHROOM EAST WALL
9) BLOCK FRONT PORCH BELOW LEDGER FOR STUCCO MESH FASTENERS 6"
10) NOT ABLE TO LOCATE REVISION OF REMOVED WINDOWS SOUTH WALL 4 AND 5
11) TRIMMERS MISSING CLOSET DOOR SOUTHWALL
12) ANCHOR BOLTS AND NUTS MISSING THROUGHOUT MARKED
03/30/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) REMOVE SCREEN FROM DRYER VENT T-T? 2) BLOCK MECH ON 3 SIDES. 3) NO TEST ON DWV'S. 4) FIRE BLOCK DROP CEILING AREAS AND SOFFIT. 5) GROUT TUBS 6) 110 OUTLET FOR STOVE MISSING7) STRAP HEADERS AND SHIM. 8) 2 WINDOWS DELETED REVISE PLANS. 9) ELECT NOT COMPLETE. 10) STOPPED INSP. TO MANY ITEMS 11) INSP 3035, 1015 NOT APPROVED PROVIDE PROOF. 12) LATH UNDER FRONT OVERHANG NOT STAPPLED & MISSING BLOCKS