Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM05608

Parcel: 140323050

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM05608

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/07/2005 FRAMING Approved IVRS - Inspection :*
04/14/2005 FRAMING Partial Approval IVRS - Inspection :*
1) HAVE TRUSS REPAIR DOCUMENT APPROVED BY CITY OF TUCSON
2) OK TO DRY WALL
03/29/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) TWO HOLD DOWNS AT REAR OF HOUSE NOT INSTALLED 2) FIRE STOP HALL ARCH. 3) PROVIDE TRUSS REPAIR DOCUMENTS FOR ITEM 6 OF 3/22/05 INSP. 4) PROVIDE CITY OF TUCSON APPROVED TRUSS ENGINEERS APPROVED DOCUMENTS FOR DAMAGED TRUSS. 5) TRUSS GANG NAIL GUSSET PLATES APPEAR TO HAVE BEEN INSTALLED WITH HAMMERS. 6) HAVE TRUSS ENGINEER PROVIDE INSULATION OF INSTALLED GANG NAILS. 7) NEXT FAILURE WIL BE CHARGED A REINSPECTION FEE.
03/22/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ATTIC ACCESS BLOCKED BY DUCTWORK
2) HALL DWV VENT OUT OF WALL
3) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE W/C
4) FIRESTOP HALL ARCH
5) BEDROOM SHEARWALL NOT NAILED PER 2/D3
6) TUB TRUSS DAMAGED 4 HOLES DRILLED FOR ELECTRIC 7) POPOUTS NOT COMPLETE
8) MASTER BATH TWO HOLDOWNS MISSING, SEE CLIP