Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM05608
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/07/2005 | FRAMING | Approved | IVRS - Inspection :* | |
04/14/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) HAVE TRUSS REPAIR DOCUMENT APPROVED BY CITY OF TUCSON 2) OK TO DRY WALL |
|
03/29/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TWO HOLD DOWNS AT REAR OF HOUSE NOT INSTALLED 2) FIRE STOP HALL ARCH. 3) PROVIDE TRUSS REPAIR DOCUMENTS FOR ITEM 6 OF 3/22/05 INSP. 4) PROVIDE CITY OF TUCSON APPROVED TRUSS ENGINEERS APPROVED DOCUMENTS FOR DAMAGED TRUSS. 5) TRUSS GANG NAIL GUSSET PLATES APPEAR TO HAVE BEEN INSTALLED WITH HAMMERS. 6) HAVE TRUSS ENGINEER PROVIDE INSULATION OF INSTALLED GANG NAILS. 7) NEXT FAILURE WIL BE CHARGED A REINSPECTION FEE. |
|
03/22/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ATTIC ACCESS BLOCKED BY DUCTWORK 2) HALL DWV VENT OUT OF WALL 3) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE W/C 4) FIRESTOP HALL ARCH 5) BEDROOM SHEARWALL NOT NAILED PER 2/D3 6) TUB TRUSS DAMAGED 4 HOLES DRILLED FOR ELECTRIC 7) POPOUTS NOT COMPLETE 8) MASTER BATH TWO HOLDOWNS MISSING, SEE CLIP |