Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/07/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
03/04/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) BOTH PAHD 22'S AT REAR SHEAR TOO MUCH SPALLING, NEED RETRO/FIT EPOXY BOLTED H.D.'S CHECK AT INTERMEDIATE 2) FRONT HIP TRUSSES LARGE GAP AT CONNECTION TO GIRDER TRUSS INSTALL LU 24 HANGERS MINIMUM AT TOP CHORD |