Permit: T04CM05608

Parcel: 140323050

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM05608

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/07/2005 EXT METAL CLIPS/EXT SHEATHING Approved
03/04/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) BOTH PAHD 22'S AT REAR SHEAR TOO MUCH SPALLING, NEED RETRO/FIT EPOXY BOLTED H.D.'S CHECK AT INTERMEDIATE
2) FRONT HIP TRUSSES LARGE GAP AT CONNECTION TO GIRDER TRUSS INSTALL LU 24 HANGERS MINIMUM AT TOP CHORD