Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) FREEZE BOARDS PER DETAILS AZ SECTION 1 |
|
| 06/30/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSED ROWS AT NORTH END 2) NEED STUD CLIPS, HEADER STRAPS AND TOP PLATED STRAPPED OR OSB'D 3) H2.5 LEDGERS WHERE A-35 TABS ARE NOT FOLDED |
|
| 06/09/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BRACED WALL PANELS NOT PER PLAN 2) NAILING SET TO DEEP OR STICKING UP 3) FILL ALL HOLES H2.5'S-A-35'S 4) INSTALL BOLTS EACH END BRACED WALL PANELS 5) INSTALL BOLTS WITHIN 12" EACH END BOTTOM PLATES 6) PORCH NOT FRAMED PER PLAN 7) STOPPED INSPECTION |