Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 07/20/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FURNACE SPARK SHIELD NOT UNDER GRILL. SEE INSTALLATION INSTRUCTIONS 2) INSTALL JACUZZI ACCESS PANEL 3) HANDRAIL ON STRIP NOT PER CODE 4) SEAL DRYWALL PENETRATIONS 5) SEAL 2ND FLOOR TUB PENETRATION |
|
| 07/19/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HANDRAIL MUST BE 36" PLUS OR MINUS 2" AND PARALLEL TO STAIR BULL NOSE 2) KITCHEN GFCI REQUIRED WITHIN 24" OF COUNTER END 3) JACCUZI TUB NEED GFCI MOVED AND SECURED AND ACCESS 4) FURNACE VENT REVERSE PITCH MOVE SPARK SHIELD |
|
| 07/18/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JOE |