Permit: T04CM05481

Parcel: 138220740

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/08/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/31/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOLDOWN NEXT TO KITCHEN WINDOW NOT NAILED TO TWO KING STUDS
2) CLIPS MISSING NAILS
3) CHECK SHEAR FOR NAILING
4) NAIL PROTECT WATER LINE
5) BLOCK SHEAR AT WATER LINE
6) CHECK FOR OVERSPANS
7) KING STUDS MISSING EACH SIDE OF 6 DEGREE WINDOW OPENING
8) HOLDOWN NORTH EAST SIDE NOT NAILED TO TWO KING STUDS
9) ROOF SHEATHING MUST SPAN TWO BAYS
10) STOPPED INSPECTION TO MANY ITEMS