Permit: T04CM05480

Parcel: 12905130L


Addresses:

2140 E WINSETT ST

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
09/15/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
09/16/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
WATER TEST 2-3" BUILDING DRAINS FROM RESTROOMS STUDDED OUT OF BUILDING PER PLAN
1) WILL NEED TO SEE PIPE WRAPS PRIOR TO CONCRETE
2) CONTINUATION OF BUILDING SEWER FROM 2-WAY CLEANOUTS TO HCS
09/09/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) WATER TEST IS DOWN
2) TRAILER LOCKED
3) NO ONE ON SITE
4) IS PLUMBING AT WEST END GOING TO BE EXPOSED IN A FOOTING ?
09/09/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 3" DRAINAGE REQUIRES MINIMUM 1/4" PER FOOT FALL
2) YOU CANNOT RUN DRAINAGE PIPING PARALLEL IN A FOOTING OR WITHIN THE ANGLE OF REPOSE
3) PROVIDE 4" SEWER PER APPROVED PLAN