Permit: T04CM05451

Parcel: 140383680

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
06/10/2005 BUILDING - FINAL Approved IVRS - Inspection :*
06/06/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) A/C CONDENSOR BLOCKS ACCESS TO DISCONNECT
2) FURNACE CABINET BENT TWO INCHES. COVERS WILL NOT INSTALL REPAIR OR REPLACE UNIT. RE-SUPPORT PER INSTALLATION INSTRUCTIONS
3) M/BATH W/C HAS LESS THAN 15" TO CENTER OF FLANGES
06/03/2005 BUILDING - FINAL Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) LABEL ALL CIRCUITS IN ELECTRIC PANEL
2) ELECTRIC SERVICE REQUIRES NON WATER BOND LABEL
3) ACCESS TO A/C DISCONNECT BLOCKED BY CONDENSOR UNIT. PROVIDE 30" X 30" UNOBSTRUCTED ACCESS
4) ALL GARAGE CONVENIENCE OUTLETS MUST BE GFCI PROTECTED
5) TO MANY ITEMS-STOPPED INSPECTION