Permit: T04CM05451

Parcel: 140383680

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/19/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/11/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL 2 NAILS EACH END WIND BRACING
2) INSTALL METAL PROTECTION EXTERIOR BOTTOM PLATES
3) PLUMBING CUT OUT 3 1/2 INSTALL A35F TOP OF SHEARWALLS AT 16" SPACING
4) REPLACE DAMAGED OSB REAR SHEARWALL
5) INSTALL RETROFIT HOLDOWNS (EXCESS SPALLING)
6) INSTALL WIND BRACING MAX 25' OF RUN EXTERIOR AND TRUSS CROSS BRACES
7) SHEARWALL 7 REQUIRES 3"-12" NAILING
8) COMPLETE NAILING ALL BLOCKING THROUGH ROOF HINGE BRACE BLOCKING, GARAGE S.W. TRANSFER ETC. AND VERT BOARD 2 X BLOCKING AT EXTERIOR BEARING
9) INSTALL POSITIVE CONNECTION PORCH LEDGER TO BEARING AT HOUSE CONNECTION WALL