Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM05449
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/28/2005 | FRAMING | Approved | IVRS - Inspection :*A | |
01/19/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
01/18/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING H2.5 CLIPS MISSING INTERIOR WALLS BEARING 2) INSTALL POST CAPS AT BEAMS 3) GROUND ALL METAL BOXES 4) PROVIDE 1 1/4" AT TOP PLATE FOR HOMERUNS AT NEW SERVICE 5) INSTALL 4 BOLT HUB AT RISER 6) COMPLETE KITCHEN STOVE EXHAUST |