| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/23/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/22/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH PREVIOUS INSPECTION 4, 5 AND 6 2) LOOSE SHEET MARKED ABOVE MASTER BEDROOM 3) DIAGRAM NAILING MARKED ON FLOOR |
|
| 03/18/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT PLUMBING 2) EXPOSE PORCH COLUMNS 3) MISSING NAILS WIND BRACE N.W. CORNER 4) LOOSE SHEETS MARKED AT ENTRY AND MASTER BEDROOM 5) MISSING CLIP WEST WALL 10TH STUD FROM NORTH TOP PLATE 6) MISSING WIND BRACE NORTH EXTERIOR WALL OVER 35' SPAN 7) MISSING CLIP GARAGE WEST WALL BASE PLATE 8) COMPLY WITH GABLE TRUSS DETAIL 1/SD-3 2 X 4 X 8 BRACE 5'-4" FROM END OF WALL |