Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 06/13/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) GAS FLEX CANNOT ENTER FURNACE COMPARTMENT, MUST BE HARD PIPED 2) APPLIANCES MUST HAVE A DRIP LEG |
|
| 06/09/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) INTER CONNECT SMOKIES 2) INSTALL SRU (FUSED RECEPTACLE AT FURNACE) 3) INSTALL GAS LINE TO FURNACE; HAVE DRIP LEG ON FURNACE AND WATER HEATER 4) INSTALL VACCUM BREAKER ON HOSE BIB 5) A/C UNIT CALLS FOR MAXIMUM 35 AMP FUSES, 40'S INSTALLED |
|
| 06/01/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) CHANGE FURNACE RECEPTACLE TO FUSED RECEPTACLE 2) INSTALL S/D, LIGHTS AND RECEPTACLE 3) REMOVE 10' TEST PIPE 4) INSTALL GAS LINE TO FURNACE 5) NEED 90 ON T/P VALVE 6) INSTALL C/O COVER EAST SIDE 7) INSTALL LAV'S 8) A/C NOT STARTED 9) SECURE ELECTRIC WHIP TO HOUSE 10) CONDENSATE RUNS INTO T/P LINE |