Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T04CM05437

Parcel: 11713061K

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
01/07/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :* 1) SOIL WATER TEST IS OK 2) P.O.C OF NEW BLDG DRAIN TO EXISTING BLDG DRAIN IS OK 3) OK TO BACKFILL TRENCH 4) HOT & COLD WATER ??OK IN WALL
01/06/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)APPROVED PLANS CALL FOR FLOOR C.O. AND THERE IS ENOUGH DEPTH FOR THIS. 2)PLANS CALL FOR VENTS AND WASTE TO BE CAST IRON 3)RE TEST SYSTEM
12/28/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)NO APPROVED PLANS ON SITE 2)NO UNIT NUMBER POSTED 3)SHALL PROVIDE WATER TEST ON SYSTEM 4)FLOOR C.O. REQUIRED WHERE HORIZONTAL DRAIN EXCEEDS 135 DEGREES 5)DO NOT COVER