Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/08/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) PLBG FINAL IS OK. 2) OK FOR C OF O | |
| 06/30/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL PROVIDE AN EXPANSION TANK FOR WATER HTR. 2) SHALL PROVIDE VACUUM BREAKERS @ ALL EXTERIOR HOSE BIBS. 3) SHALL PROVIDE C.O @ HAND SINK AND @ END OF CONTINUOUS WASTE FOR 3 COMPT SINK. 4) SHALL PROVIDE 3" WASTE FROM OUTLET OF FLOW CONTROL. 5) SHALL SECURE GAS LINE BEHIND COOKING EQUIPMENT. 6) SHALL PROVIDE OPEN FRONT SEAT @ WATER CLOSET. |
|
| 06/29/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLDG WAS LOCKED! |