Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/10/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/25/2005 | FRAMING | Partial Approval | 1) EXTEND TEMP RELIEF LINE TO EXTERIOR WALL 2) DON'T USE FEMALE PLASTIC PVC FITTING WITH AMLE COPPER, USE COPPER FEMALE, PLASTIC MALE 3) CAN'T HAVE GAS LINE EMBEDDED IN CONCRETE 4) WASHER DRAIN NOT PLUMBED CORRECTLY 6) CUT NAIL BOTTOM PLATES TO FOOR 7) FINISH WIRING CEILING LIGHT 8) WRAP ALL FITTINGS WITH MILL TAPE |
|
| 01/12/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 1" CLEARANCE FROM COMBUSTIBLES REQUIRED AT DBL WALL VENT AT WATER 2) REPLACE PVC WATER LINES WITH COPPER OR GALV. IRON 3) PTR LINE SHALL EXTEND 6" MINIMUM 24" MAXIMUM FROM FINISH FLOOR 4) GAS GUAGE AT GAS LINE IS "0" 10 POUND MINIMUM REQUIRED 5) EXPOSE SEWER LINES TO CLOTHES WASHER NOT TRAP VENT OF CLEANOUT VISIBLE 6) NO APPROVED PLANS OR PERMITS ON SITE 7) STOPPED INSPECTION |