Inspection Status: Approved
Inspection History: ELECTRIC - ABOVE CEILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/30/2006 | ELECTRIC - ABOVE CEILING | Approved | IVRS - Inspection :* | |
| 02/08/2006 | ELECTRIC - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* | |
| 02/01/2006 | ELECTRIC - ABOVE CEILING | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. MANUFACTURERS LIGHT FIXTURES TO BE EFFECTIVE CLIPS 2. SUPPORTING IF USED FOR FIXTURE WHIPS TO BE AS PER 300.11 RELOC AND 3. BOXES IN GRID TO HAVE SUPPORT WIRES 4. CONDUIT TO BE SUPPORTED WITHIN 3' AND 6' ALSO AS PER 300.11 ALSO ABOVE HARD CEILING. 5. VDV CABLING TO BE INDEPENDENTLY SUPPORTED 6. PLEASE VERIFY CONDUCTOR FILL IN BOXES 7. FILL UNUSED OPENINGS IN JUNCTION BOXES 8. JUNCTION BOXES TO BE ACCESSIBLE ALSO AS PER TUSD INSPECTOR |
|
| 01/30/2006 | ELECTRIC - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* |