Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/01/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/31/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) U24 HANGER MISSING NAILS 2) P-3 SHEAR REQUIRES A.B.'S AT 16" ON CENTER 3) NAIL PROTECT WIRES AND PLUMBING WITHIN 1 1/4" OF STUD SURFACE 4) SEWER VENT CANNOT BE WITHIN 10 FT OF INTAKE AIR 5) SHIM HEADERS 6) STACK OUT OF WALL CAVITY AT PANTRY 7) FILL 2ND FLOOR DWV |
|
| 05/25/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 05/10/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) NO PRIOR INSEPCTION REPORT ON SITE 2) MANY ANCOR BOLTS MISSING THRU-OUT 3) LVL BEAM NOT NAILED PER PLAN 4) LVL HAS INCORRECT HANGERS 5) P-3 SHEAR WALL NOT NAILED PER PLAN NAILS DRIVEN TO DEEP 6) PROVIDE 12 EACH A35 AT P3 SHEAR PER PLAN 7) ANCHOR BOLTS LOOSE 8) STOPPED INSPECTION-TO MANY ITEMS 9) SUPERINTENDENT TO INSURE HOUSE IS COMPLETE PRIOR TO NEXT INSPECTION. NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE |
|
| 05/09/2005 | FRAMING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* 1) NO PLANS OR PERMIT ON SITE |
|
| 05/06/2005 | FRAMING | Cancelled | IVRS - RI canceled |