Permit: T04CM05404

Parcel: 12314080A


Addresses:

1920 N 1ST AV

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
02/04/2005 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
02/03/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245* 1) SMOKE DETECTORS ARE NOT ALLOWED TO BE MOUNTED CLOSER THAN THREE ( 3') FEET TO ANY AIR REGISTER. THIS IS TO PREVENT THE SUPPLY AIR FROM BLOWING ANY SMOKE CLEAR OF THE DETECTOR. 2) THE SMOKE DETECTOR MUST NOT BE CLOSER THAN SIX ( 6) INCHES TO THE WALL AND NOT FARTHER THAN 12" . THIS IS SAME IF MOUNTED ON WALL OR CEILING. PLEASE CORRECT & RECALL INSPECTION. THANKS. PS. ALL OUTLETS IN BEDROOMS MUST BE ON ARC FAULT PROTECTED CIRCUITS. MAC 909- 5147
01/26/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The smoke detectors have not been installed per code.| 165* SMOKE DETECTORS MUST BE INSTALLED IN BEDROOMS THEY MUST BE INTER CONNECTED TO ALARM SIMULTANEOULSLY, AND THEY MUST BE BOTH ELECTRICAL AND BATTERY POWERED. THANKS CORRECT & RECALL