Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/08/2005 FRAMING Approved IVRS - Inspection :*
06/06/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEAR BLOCK PNAELS NOT NAILED PER 1/SD2
2) P-2 SHEAR WALLS NAILS DRIVEN TO DEEP
3) GARAGE SHEARWALL REQUIRES ANCHOR BOLTS AT 16" ON CENTER
4) SEAL FLOOR PENETRATION
5) HOLDOWNS MISSING NUTS
6) BLOCK MECHANICAL BOOTS 3 SIDES
7) LUS 24 HANGERS MISSING
8) LEDGER AND NAILER REVERSED AT ENTRY
9) WINDOWS MUST BE 6" MINIMUM AT NARROW ENDS
10) DRAFT STOP BEDROOMS
11) UNSUPPORTED FLOOR
12) DOOR BELL MUST BE HIGHER THAN 6'-8" ABOVE STAIR
06/03/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
06/02/2005 FRAMING Denied IVRS - Inspection :
There is no plan or job inspection card on site.| 925*
05/23/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) NOT COMPLETE
05/18/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) LVL NOT NAILED PER PLAN
2) P2 SHEARWALL ANCHOR BOLTS NOT INSTALLED PER NOTE C/S-1
3) SEAL FLOOR PENETRATIONS
4) SEWER DRAINS MUST HAVE 1/4" PER FOOT FALL
5) INTERIOR BEARING WALLS REQUIRE ANCHOR BOLTS
6) MECHANICAL DUCTS RESTRICTED ABOVE DINING ROOM
7) RED HEAD ANCHOR BOLTS LOOSE
8) SHIM NON BEARING TRUSSES
9) FIREPLACE NOT WIRED OR GROUNDED
10) FIRE STOPS MUST BE TWO LAYERS 1/2" O.S.B.
11) HOLDOWNS NOT IN
12) STOPPED INSPECTION-TO MANY ITEMS