Permit: T04CM05389

Parcel: 140376690


Addresses:

6907 S HARRIER LP

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/15/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/12/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 1, 2 FROM 4/5/05 NOT CORRECTED
2) ITEM 3 FROM 4/5/05 NOT INSPECTED, NO LADDER ACCESS. NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE
3) NO PLAN/PERMIT ON SITE
04/05/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOLDOWNS MUST BE CONNECTED TO FULL LENGTH DBL STUDS
2) STUD AT EAST END OF HOUSE NOT PLUMB
3) ROOF NOT NAILED
04/01/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLIP ENDS OF GABLE END TRUSSES PER 1/SD2
2) NAIL STUDS TO PLATES, SOME LOOSE
3) ROOF SHEATHING NOT NAILED TO TRUSSES MANY LOCATIONS
4) MANY ROOF OSB PANELS TO SMALL, THEY MUST SPAN 3 TRUSSES (TWO BAYS)