Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/27/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/26/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JAMES |
|
| 04/22/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO CORNER REINFORCEMENT ON STUCCO LATH 2) LATH NOT COMPLETE AT COLUMNS AND POP OUTS 3) RED HEADS LOOSE AND AB'S LOOSE 4) FIREBLOCK CHASE GARAGE 5) SHEARWALL TOP RIBBON NOT NAILED AT 6" GARAGE 6) PEX REQUIRES 6" TO W/H B-VENT 7) NAIL EXT. 2ND FLOOR PLATES AT 16" ON CENTER SOUTH WALL AND NORTH WALL 8) NO DWV WATER TEST 2ND FLOOR 9) NAIL PROTECT WIRES 2ND FLOOR HALL BATH 10) DRYER DUCT BOOT NOT IN 11) NAIL PROTECT WIRES BR S.E. 12) W/H B-VENT 1" TO COMBUSTIBLES |