Permit: T04CM05380

Parcel: 123121260


Addresses:

1457 E HAMPTON ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04CM05380

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/13/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
09/22/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/14/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
WORK NOT COMPLETED
GAS PRESSURE TEST APPROVED BILL NORTH 11/1/05 3050
06/02/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DRIP LEGS NEEDED ROOF TOP UNITS ON APPLIANCE SIDE OF SHUT OFF VALVE, ALSO UNDER HEATERS
2) SEAL WATER CLOSET BASE
3) DISHWASHER INSTALLATION NOT COMPLETE
05/22/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE SAFE ACCESS TO ROOF
2) SEAL B-VENT AT LID
05/12/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER HEATER FLUE MUST BE APPROVED MATERIAL
2) REMOVE PAPER BACKING FROM PENETRATIONS
3) SEAL LID AT WATER HEATER FLUE
4) INTERIOR PLUMBING NOT COMPLETED
05/09/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) REQUEST GAS CARD DENIED NO DRIP LINE ON WATER HEATER
04/19/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. VACUUM BREAKERS HOSE BIBBS
2. 90 FITTINGS TPR VALVES @ EXTERIOR
3. MISSING HOSE BIBB EXTERIOR NORTH WALL
4. DISPOSAL & DISHWASHER NOT CONNECTED
5. SEAL WATER CLOSET BASE
6. PROVIDE COMPLETE SET OF APPROVED PLANS EVERY INSPECTION.
03/27/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) VACUUM BREAKERS HOSE BIBS
2) 90 FITTING NEEDED TPR VALVE EXTERIOR
3) STOPPED INSPECTION-INTERIOR PLUMBING NOT READY
08/30/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) FIRE BLOCK PLENUM WH
2) GAS LINE NORTH WALL MUST BE IN WALL
3) TERMINATE HOME RUNS IN SERVICE PANEL
4) PROVIDE GAS BOND