Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T04CM05380
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/13/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
09/22/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
06/14/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* WORK NOT COMPLETED GAS PRESSURE TEST APPROVED BILL NORTH 11/1/05 3050 |
|
06/02/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DRIP LEGS NEEDED ROOF TOP UNITS ON APPLIANCE SIDE OF SHUT OFF VALVE, ALSO UNDER HEATERS 2) SEAL WATER CLOSET BASE 3) DISHWASHER INSTALLATION NOT COMPLETE |
|
05/22/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE SAFE ACCESS TO ROOF 2) SEAL B-VENT AT LID |
|
05/12/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER HEATER FLUE MUST BE APPROVED MATERIAL 2) REMOVE PAPER BACKING FROM PENETRATIONS 3) SEAL LID AT WATER HEATER FLUE 4) INTERIOR PLUMBING NOT COMPLETED |
|
05/09/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) REQUEST GAS CARD DENIED NO DRIP LINE ON WATER HEATER |
|
04/19/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. VACUUM BREAKERS HOSE BIBBS 2. 90 FITTINGS TPR VALVES @ EXTERIOR 3. MISSING HOSE BIBB EXTERIOR NORTH WALL 4. DISPOSAL & DISHWASHER NOT CONNECTED 5. SEAL WATER CLOSET BASE 6. PROVIDE COMPLETE SET OF APPROVED PLANS EVERY INSPECTION. |
|
03/27/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) VACUUM BREAKERS HOSE BIBS 2) 90 FITTING NEEDED TPR VALVE EXTERIOR 3) STOPPED INSPECTION-INTERIOR PLUMBING NOT READY |
|
08/30/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) FIRE BLOCK PLENUM WH 2) GAS LINE NORTH WALL MUST BE IN WALL 3) TERMINATE HOME RUNS IN SERVICE PANEL 4) PROVIDE GAS BOND |