Permit: T04CM05356

Parcel: 11623049A


Addresses:

810 W 19TH ST

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
06/13/2005 BUILDING PRE-SLAB Approved IVRS - Inspection :*
06/10/2005 BUILDING PRE-SLAB Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 15" LAP REBAR SPLICES REQUIRED
2) ISOLATE REBAR DRIVEN INTO GROUND FROM HORIZONTAL STRUCTURED REBAR
3) MAINTAIN MINIMUM 3" CLEARANCE REBAR TO DIRT AND FORMS
4) EXCAVATE DIRT PLUMB DOWN FROM WOOD FORMS
06/08/2005 BUILDING PRE-SLAB Denied IVRS - Inspection :
See detailed listing on site.| 999*