Permit: T04CM05346

Parcel: 120085320

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T04CM05346

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/04/2005 BUILDING - FINAL Approved IVRS - Inspection :*
11/03/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CIRCUIT #18 AND 24/26 NOT IDENTIFIED
2) SEAL KNOCKOUT AT PANEL (BOTTOM)
3) T & P LINE AT WATER HEATER MISSING AT 90 DEGREE ELBOW
4) VTR NORTH WALL MUST BE PROTECTED FROM THE ELEMENTS
5) EXTERIOR OUTLET NOT GFCI PROTECTED
6) GFCI BEHIND REF. DOES NOT RESET
7) CANNOT HAVE MORE THAN 1/8" GAP AT ELECTRIC BOXES
8) NEED ACCESS TO ROOF
9) ANTI-TIP DEVICE MISSING AT STOVE
08/16/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ANTI-TIP REQUIRED AT STOVE
2) SECRUE EXTERIOR LIGHT TO BOX OUTLET MISSING, AT 12" COUNTER LEFT OF STOVE
3) 2 GFI CIRCUITS REQUIRED IN KITCHEN
4) REVISE PLAN TO REFLECT AS BUILT IN KITCHEN CABINET LAYOUT
5) EXTENSION CORD NOT ALLOWED ON KITCHEN HOOD OVER STOVE BURNER, CONTACT TO OUTLET ABOVE
6) OUTLET COVER MISSING IN MASTER BATHROOM
7) GFI COVER MISSING AT EXTERIOR OUTLET
8) J-BOX COVER REQUIRED AT WATER HEATER J-BOX
9) FLEX AT EXTERIOR LIGHT S.W. CORNER SHALL BE RAIN TIGHT FITTING ALSO
10) P.T.L. SHALL DISCHARGE DOWNWARD 6" MINIMUM 24" MAX FROM GROUND
12) PROVIDE ROOF ACCESS
13) MOVE ALL FURNITURE AWAY FROM WALLS
14) PROVIDE ROOF ACCESS
15) STOPPED INSPECTION