Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/16/2005 |
SHEET ROCK NAILING |
|
Approved |
IVRS - Inspection :* |
| 05/11/2005 |
SHEET ROCK NAILING |
|
Partial Approval |
IVRS - Inspection :* 1) APT SIDE OF 2 HR WALL OK 2) PATCH 1/2" CEILING @ BREAKROOM THEN INSTALL HOT CHANNEL AND RECALL INSPECTION. 3) ABOVE CEILING IN BATHROOM MUST BE 2 HR ( EXTEND 2 LAYER 5/8 GYP TO BOTTOM OF JOIST) |