Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/28/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 07/27/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* KITCHEN COUNTER ON NORTH WALL MUST HAVE GFCI PROTECTED OUTLET WITHIN 24" OF END OF COUNTER OVER THE COUNTER - NOT 24" OFF THE END OF COUNTER |
|
| 07/26/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) RELOCATED 220V A/C CABLE RUN OK TO COVER |
|
| 07/25/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL COMBUSTION AIR WEATHER GRILLS 2) FILL HOLES IN STUCCO 3) PROVIDE 4" CLEARANCE TO STUCCO WEEP SCREED 4) A/C HAS BEEN RELOCATED 5) PROVIDE PROOF TAHT 220 CABLE IS NOT SPLICED IN CAVITY 6) GFCI OUTLETS WITHIN 24" OF COUNTER END KITCHEN 7) DISHWASHER DRAIN REQUIRES LOOP TO 2" OF FLOOD RIM 8) FRONT BEDROOMS INDICATE SHARED NEUTRAL FAULT |