Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/02/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE STOP GARAGE CHASE 2) NAIL SHEAR BLOCK PANELS 3) P-3 SHEAR REQUIRES AB'S AT 16" ON CENTER 4) FIREBLOCK MISSING M.BR 5) DRAFT STOP DUCT WORK 6) LAUNDRY OUT OF WALL 7) NAIL PROTECT PLUMBING 8) NAIL PROTECT WIRES 9) WASTE VENT WITHIN 10 FT OF FRESH AIR INTAKE 10) LOOSE AND MISSING ANCHOR BOLTS 11) 3" SANITARY T NOT ALLOWED IN HORIZONTAL DRAIN M/BATH 12) GAS PRESSURE TEST OK |
|
| 06/01/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) STUCCO LATH NOT STAPLED/NAILED AT BOTTOM PLATE OR COMPLETE 2) RED HEAD ANCHOR BOLTS LOOSE 3) HOUSE INSULATED W/O INSPECTION-REMOVE ALL INSULATION |