Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/02/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT WIRES ( 220) WITHIN 1 1.4" OF WALL SURFACE. 2) A/C LINES OUT SIDE OF WALL CAVITY. 3) TWO STUDS MISSING EAST WALL. 4) NO GAS TEST. |
|
| 04/28/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 04/25/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) SEAL STUCCO WALL PENETRATIONS 2) NO WATER POTABLE TEST 3) NO DWV WATER TEST 4) KITCHEN SINK REQUIRES VERT TO ROOF 5) PEX CANNOT BE WITHIN 12" OF CAN LIGHT 6) NO GAS PRESSURE TEST 7) STAIR LEDGER CANNOT BE HUNG ON 1/2" OSB SEE 49/AD3 8) STOPPED INSPECTION TO MANY ITEMS. HOUSE NOT READY |
|
| 04/22/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) PER JAMES |