Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/10/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/09/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JAMES |
|
| 05/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LEAK AT KITCHEN DIRTY ARM DWV 2) SECOND FLOOR SHORT HEADER TO SHORT TO BEAR ON DBL 2 X POST. SEE PLAN |
|
| 05/02/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) NO DWV WATER TEST. 2) SEAL FLOOR PENETRATIONS. 3) NO GAS PRESSURE TEST. 4) SECURE HOSE BIB. 5) 2ND FLOOR SHORT BEAM TOO SHORT PROVIDE POST ON N.W END. 6) NAIL 2ND FLOOR SILL PLATES AT 16' ON. SHEAR AT 12". 7) FIRE STOP BETWEEN GARAGE & 2ND FLOOR. 8) PROVIDE 22 X 48" ACCESS TO LOW ROOF OVER FRAME. 9) P-1 SHEAR WALL NOT INSTALLED AT SECOND FLOOR. 10) POST MSSING UNDER 2ND FLOOR STOPPED INSPECTION TOO MANY ?? |