Permit: T04CM05267

Parcel: 140376490


Addresses:

6902 S HARRIER LP

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/14/2005 FRAMING Approved IVRS - Inspection :*
04/12/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LATH NOT COMPLETE AT GABLE END VENT AND GARAGE
2) LATH NOT STAPLED UNDER PORCH LEDGER
3) PROVIDE BACKING BOARD UNDER LEDGER FOR PORCH
4) PATIO RAFTERS NOT SUPPORTED PER 15A/SD3.1
5) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE
6) REMOVE STAPLES FROM BEHIND 1" PEX
7) RED HEAD ANCHOR BOLTS LOOSE
8) A/C COPPER OUT OF WALL
9) PROVIDE 22 X 48" LOW ROOF OPENING